4.7 Article

Comparison of contrast-enhanced CT, dual-layer detector spectral CT, and whole-body MRI in suspected metastatic breast cancer: a prospective diagnostic accuracy study

期刊

EUROPEAN RADIOLOGY
卷 31, 期 12, 页码 8838-8849

出版社

SPRINGER
DOI: 10.1007/s00330-021-08041-2

关键词

Breast neoplasms; Neoplasm staging; Whole-body imaging; Tomography; X-ray computed; Diffusion magnetic resonance imaging

资金

  1. Health Research Foundation of Central Denmark Region

向作者/读者索取更多资源

The study compared the diagnostic accuracy of contrast-enhanced CT, dual-layer detector spectral CT (DL-CT), and whole-body MRI (WB-MRI) for detecting metastatic breast cancer. Results showed that DL-CT had significantly higher diagnostic performance and sensitivity per lesion compared to CT and WB-MRI, while on a per-patient basis, DL-CT and WB-MRI had superior diagnostic performance to CT.
Objectives To compare diagnostic accuracy of contrast-enhanced CT, dual-layer detector spectral CT (DL-CT), and whole-body MRI (WB-MRI) for diagnosing metastatic breast cancer. Methods One hundred eighty-two biopsy-verified breast cancer patients suspected of metastatic disease prospectively underwent contrast-enhanced DL-CT and WB-MRI. Two radiologists read the CT examinations with and without spectral data in consensus with 3-month washout between readings. Two other radiologists read the WB-MRI examinations in consensus. Lymph nodes, visceral lesions, and bone lesions were assessed. Readers were blinded to other test results. Reference standard was histopathology, previous or follow-up imaging, and clinical follow-up. Results Per-lesion AUC was 0.80, 0.84, and 0.82 (CT, DL-CT, and WB-MRI, respectively). DL-CT showed significantly higher AUC than CT (p = 0.001) and WB-MRI (p = 0.02). Sensitivity and specificity of CT, DL-CT, and WB-MRI were 0.66 and 0.94, 0.75 and 0.95, and 0.65 and 0.98, respectively. DL-CT significantly improved sensitivity compared to CT (p < 0.0001) and WB-MRI (p = 0.002). Per-patient AUC was 0.85, 0.90, and 0.92 (CT, DL-CT, and WB-MRI, respectively). DL-CT and WB-MRI had significantly higher AUC than CT (p = 0.04 and p = 0.03). DL-CT significantly increased sensitivity compared to CT (0.89 vs. 0.79, p = 0.04). WB-MRI had significantly higher specificity than CT (0.84 vs. 0.96, p = 0.001) and DL-CT (0.87 vs. 0.96, p = 0.02). Conclusions DL-CT showed significantly higher per-lesion diagnostic performance and sensitivity than CT and WB-MRI. On a per-patient basis, DL-CT and WB-MRI had equal diagnostic performance superior to CT.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据