4.7 Article

Multi-residue analysis of 20 mycotoxins including major metabolites and emerging mycotoxins in freshwater using UHPLC-MS/MS and application to freshwater ponds in flanders, Belgium

期刊

ENVIRONMENTAL RESEARCH
卷 196, 期 -, 页码 -

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.envres.2020.110366

关键词

Mycotoxins; Pond water; SPE-UHPLC-MS; MS; Method development; Multi-residue analysis

资金

  1. Special Research Fund of Ghent University, Belgium [BOF16GOA024.08]

向作者/读者索取更多资源

This study developed a method for detecting and quantifying multiple mycotoxins in amphibian breeding ponds, showing good performance in various aspects. Storing and analyzing water samples within 96 hours after sampling can prevent degradation losses, and multiple mycotoxins were detected in the water samples.
Mycotoxins are known for their negative impact on human and animal health as they frequently contaminate food and feed products from crop origin that are consumed by humans and animals. Furthermore, mycotoxins can leach out of plant tissue, to be transported through runoff water into nearby ponds where they can exert negative effects on aquatic organisms, such as fish, amphibians and zooplankton. The overall goal of this study was to develop a SPE-UHPLC-MS/MS method for the detection and quantification of multiple mycotoxins in amphibian breeding ponds. The method was validated and yielded acceptable within-run and between-run apparent recoveries and precision, as well as good linearity. Matrix effects (i.e. 75.7?109.6%, < 17.8% RSD) were evaluated using water from 20 different ponds in Flanders, Belgium. By incorporating internal standards, overall results improved and adequate precision values (i.e. < 15%) were obtained according to the EMA guideline. Additionally, extraction recovery (n = 3) was evaluated, yielding good results for all mycotoxins (i.e. 75.3?109.1%, <15% RSD), except for AME (i.e. 6.7 ? 0.7%), which implied the need for a matrix-matched calibration curve. Detection sensitivity was in the low nanograms per liter range. Storage stability experiments indicated that sample storage at 4 ?C in amber glass bottles and analysis performed within 96 h after sampling was sufficient to avoid loss by degradation for all compounds, excluding 8-ZAL and 8-ZEL, for which analysis within 24 h is more indicated. The method was successfully applied to water samples originating from 18 amphibian breeding ponds situated across Flanders. Overall, enniatins B, B1 and A1 were most commonly detected at maximum concentrations of 6.9, 3.3 and 2.6 ng L-1, respectively, followed by detection of beauvericin (1.1 ng L-1 and < 1 ng L-1), alternariol monomethyl ether (< 10 ng L-1), HT2-toxin (< 40 ng L-1), zearalenone (< 25 ng L-1) and ?-zearalanol (< 10 ng L-1). We believe that this method will boost further research into the dynamics and ecotoxicological impact of mycotoxins in aquatic environments.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据