4.7 Article

Experimental study of the static and dynamic behavior of pre-stressed concrete subjected to shear loading

期刊

ENGINEERING STRUCTURES
卷 234, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2021.111865

关键词

Punch-through shear test; Confinement; Split Hopkinson bar; Mode II fracture; Strain-rate sensitivity

资金

  1. CEA-Gramat Research Center (France)
  2. doctoral school IMEP2 of Grenoble Alpes University
  3. LabEx Tec 21 (Investissements d'Avenir) [ANR-11-LABX-0030]

向作者/读者索取更多资源

In this research, the static and dynamic shear strength of concrete was investigated using PTS tests, which apply axial load to generate shear stresses in the ligament of the sample. The results showed that shear strength is sensitive to water content and loading rate.
In the present work, the static and dynamic shear strength of concrete is investigated by means of Punch-Through Shear (PTS) tests. This experimental method consists in applying an axial load to the central part of the specimen which generates shear stresses in the ligament of the sample. Prior to the shearing stage, the concrete sample is subjected to a lateral confinement pressure that is applied by pre-stressing a metallic cell and then inserting the sample in-between the cell jaws so the confinement stresses are transferred to the concrete specimen during the unloading. The originality of this method lies then in the fact that the level of confinement is better controlled than the experimental protocols which can be found in the literature. A standard hydraulic press was used to conduct quasi-static experiments whereas a modified Split Hopkinson Pressure Bar device was used to perform the dynamic tests. The confinement cell is instrumented with strain gages so the confinement level applied to the ligament of the concrete specimen is measured before and during the shearing stage. The results on two sets of samples (dry and wet) shows that the shear strength is sensitive to the water content with higher values for dry samples and to the applied loading rate, with higher values of dynamic shear strength compared to static ones for both concretes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据