4.7 Article

Integrated sensor data processing for occupancy detection in residential buildings

期刊

ENERGY AND BUILDINGS
卷 237, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2021.110810

关键词

Decision tree; Machine learning; Occupancy; Co-simulation; IoT; CPS

资金

  1. NIST via federal award [70NANB19H136]

向作者/读者索取更多资源

This paper introduces a cost-effective approach to occupancy detection using a two-layer detection scheme based on data obtained from multiple non-intrusive sensors. Machine learning is utilized for data fusion, enhancing the validity and reliability of occupancy detection. The proposed system shows significant improvements in accuracy and F1-score compared to the current state-of-the-art approach.
Based on the data from U.S. Energy Information Administration (EIA), the total annual energy consumed by buildings in the United States has increased by 325% over the past 70 years. Many commercial buildings utilize a building management system (BMS) and occupancy sensors to better control heating, ventilation, and air conditioning (HVAC) systems. However, the complex and costly installation process of occupancy sensors prolongs the return on investment for the residential sector. This paper presents a cost-effective approach to occupancy detection utilizing a two-layer detection scheme based on data obtained from multiple non-intrusive sensors (temperature and motion). The sensor data were consumed by multiple heuristic models (lower layer) for recognizing a set of human activities (door handle touch, water usage, and motion near the door area). As non-intrusive sensors, such as temperature sensors, may lead to less accurate occupancy information, a data fusion scheme using machine learning (upper layer) is utilized to holistically validate any individual sensor. The proposed two-layer methodology enhances the validity and reliability of occupancy detection. The human activities data was used to train and test four machine learning models (Random Forest, Decision Tree, K-Nearest Neighbor, and Support Vector Machine). The proposed occupancy detection system was installed in a 62 m(2) living lab. Four temperature sensors and one motion sensor were used to collect the environmental information for 54 days. The validity of the proposed detection system was verified by the accuracy and the F1-score of each model. In all machine learning models, the two-layer detection system showed significant improvements to the accuracy and the F1-score over the current state-of-the-art approach with the same data. As such, the proposed work demonstrated similar or improved level of the accuracy (95%) and Fl-score (95%) over other works, while using reduced sensor density. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据