A novel approach for sizing thermal and electrical energy storage systems for energy management of islanded residential microgrid

期刊

ENERGY AND BUILDINGS
卷 238, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2021.110850

关键词

Microgrid; Lithium-Ion battery; TCL; TESS

向作者/读者索取更多资源

This paper proposes an energy management scheme for islanded operation of a residential Microgrid using a Lithium-Ion battery energy storage system and distributed generators. By replacing air conditioners with a Thermal energy storages, the total energy consumption of the Microgrid and the required LIB capacity for energy management can be significantly reduced during islanded operation.
This paper proposes an energy management scheme (EMS) for islanded operation of a residential Microgrid (MG) using a Lithium-Ion battery (LIB) energy storage system (LIBESS) and distributed generators (DGs). The LIBESS handles primary frequency control and energy management during peak-load period while the dispatchable DGs supply the base load. During peak-load periods, the thermostatically controlled loads (TCLs) like air conditioners (ACs) make up a significant part of MG demand. A Thermal energy storages (TES) is quite similar to a TCL except that it can also store thermal energy for later use. Here, instead of using the ACs, it is proposed to use a TESS to provide the required thermal energy for keeping the inside temperatures of residences within the desired range. Instead of using the ACs, a pre-charged TES can be used to provide the needed cooling thermal energy during islanded operation that power generation capacity is insufficient. By not using the ACs, the total energy consumption of MG and the required LIB capacity for energy management decreases considerably. Various daily scenarios from available recorded data and randomly generated data are used to consider the uncertainties of the variations of the MG load profile, the ambient temperature and the renewable power generations. Also, the outage of the DG with the largest generation capacity is considered as the worst contingency that could ever happen during the islanded operation of MG. The LIBESS sizing results with and without the outage of the DG show that with the ACs being totally replaced with a TES, the overall cost of the TES and the LIBESS is decreased by 33% and 63% respectively than the case that the TES is not utilized. (c) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据