4.5 Article

Semi-Analytical Solution to Assess CO2 Leakage in the Subsurface through Abandoned Wells

期刊

ENERGIES
卷 14, 期 9, 页码 -

出版社

MDPI
DOI: 10.3390/en14092452

关键词

CO2 storage; CCS; analytical solution; leakage; pressure transient analysis; abandoned wells

向作者/读者索取更多资源

This paper proposes a new semi-analytical approach based on pressure-transient analysis to model CO2 leakage behavior and pressure distribution. The method considers fluid and rock compressibilities to accurately calculate CO2 leakage rate and breakthrough time to the overburden. Numerical simulations verify the solution's accuracy and sensitivity analysis assesses different CO2 leakage scenarios. The developed approach offers a simple and practical method to evaluate CO2 leakage potential outside the storage site.
Geological carbon storage is an effective method capable of reducing carbon dioxide (CO2) emissions at significant scales. Subsurface reservoirs with sealing caprocks can provide long-term containment for the injected fluid. Nevertheless, CO2 leakage is a major concern. The presence of abandoned wells penetrating the reservoir caprock may cause leakage flow-paths for CO2 to the overburden. Assessment of time-varying leaky wells is a need. In this paper, we propose a new semi-analytical approach based on pressure-transient analysis to model the behavior of CO2 leakage and corresponding pressure distribution within the storage site and the overburden. Current methods assume instantaneous leakage of CO2 occurring with injection, which is not realistic. In this work, we employ the superposition in time and space to solve the diffusivity equation in 2D radial flow to approximate the transient pressure in the reservoirs. Fluid and rock compressibilities are taken into consideration, which allow calculating the breakthrough time and the leakage rate of CO2 to the overburden accurately. We use numerical simulations to verify the proposed time-dependent semi-analytical solution. The results show good agreement in both pressure and leakage rates. Sensitivity analysis is then conducted to assess different CO2 leakage scenarios to the overburden. The developed semi-analytical solution provides a new simple and practical approach to assess the potential of CO2 leakage outside the storage site. This approach is an alternative to numerical methods when detailed simulations are not feasible. Furthermore, the proposed solution can also be used to verify numerical codes, which often exhibit numerical artifacts.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据