4.7 Article

A U-Net based framework to quantify glomerulosclerosis in digitized PAS and H&E stained human tissues

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.compmedimag.2021.101865

关键词

Glomeruli classification; Deep learning; Digital pathology

资金

  1. National Science Center (Poland) [UMO-2016/23/N/ST6/02076]
  2. Foundation for Polish Science (FNP)

向作者/读者索取更多资源

This study developed a deep learning approach to identify and classify glomeruli in renal specimens, achieving high F1 scores in both training and testing sets using the U-Net model. The method demonstrated higher accuracy than some recent methods and provided a test image set with ground truth publicly available.
Reliable counting of glomeruli and evaluation of glomerulosclerosis in renal specimens are essential steps to assess morphological changes in kidney and identify individuals requiring treatment. Because microscopic identification of sclerosed glomeruli performed under the microscope is labor intensive, we developed a deep learning (DL) approach to identify and classify glomeruli as normal or sclerosed in digital whole slide images (WSIs). The segmentation and classification of glomeruli was performed by the U-Net model. Subsequently, glomerular classifications were refined based on glomerular histomorphometry. The U-Net model was trained using patches from Periodic Acid-Schiff (PAS) stained WSIs (n=31) from the AIDPATH - a multi-center dataset, and then tested on an independent set of WSIs (n=20) including PAS (n=6), and hematoxylin and eosin (H&E) stained WSIs (n=14) from four other institutions. The training and test WSIs were obtained from formalin fixed and paraffin embedded blocks with of human kidney specimens each presenting various proportions of normal and sclerosed glomeruli. In the PAS stained WSIs, normal and sclerosed glomeruli were respectively classified with the F1-score of 97.5% and 68.8%. In the H&E stained WSIs, the F1-scores of 90.8% and 78.1% were achieved. Regardless the tissue staining, the glomeruli in the test WSIs were classified with the F1-score of 94.5% (n=923, normal) and 76.8% for (n=261, sclerosed). These results demonstrate for the first time that a framework based on the U-Net model trained with glomerular patches from PAS stained WSIs can reliably segment and classify normal and sclerosed glomeruli in PAS and also H&E stained WSIs. Our approach yielded higher accuracy of glomerular classifications than some of the recently published methods. Additionally, our test set of images with ground truth is publicly available.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据