4.1 Article

Pilot study of a single-channel EEG seizure detection algorithm using machine learning

期刊

CHILDS NERVOUS SYSTEM
卷 37, 期 7, 页码 2239-2244

出版社

SPRINGER
DOI: 10.1007/s00381-020-05011-9

关键词

Machine learning; Seizures; Electroencephalography; Principal component analysis

向作者/读者索取更多资源

The study developed a machine learning-based seizure detection algorithm to support clinical detection of neonatal seizures, requiring only a single-channel EEG. The experimental results showed that the algorithm used 62.5% of the relative time compared to the baseline, achieving an ROC curve score of 0.91.
Objective Seizures are one of the most common emergencies in the neonatal intensive care unit (NICU). They are identified through visual inspection of electroencephalography (EEG) reports and treated by neurophysiologic experts. To support clinical seizure detection, several feature-based automatic neonatal seizure detection algorithms have been proposed. However, as they were unsuitable for clinical application due to their low accuracy, we developed a new seizure detection algorithm using machine learning for single-channel EEG to overcome these limitations. Methods The dataset applied in our algorithm contains EEG recordings from human neonates. A 19-channel EEG system recorded the brain waves of 79 term neonates admitted to the NICU at the Helsinki University Hospital. From these datasets, we selected six patients with conformational seizure annotations for the pilot study and allocated four and two patients for our training and testing datasets, respectively. The presence of seizures in the EEGs was annotated independently by three experts through visual interpretation. We divided the data into epochs of 5 s each and further defined a seizure block to label the annotations from each expert recorded every second. Subsequently, to create a balanced dataset, any data point with a non-seizure label was moved to the training and test dataset. Result The developed principal component feature-extracted machine learning algorithm used 62.5% of the relative time (only 5 s for decision) of the baseline, reaching an area under the ROC curve score of 0.91. The effect of diversified parameters was meticulously examined, and 100 principal components were extracted to optimize the model performance. Conclusion Our machine learning-based seizure detection algorithm exhibited the potential for clinical application in NICUs, general wards, and at home and proved its convenience by requiring only a single channel for implementation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据