4.7 Article

Pitolisant for Residual Excessive Daytime Sleepiness in OSA Patients Adhering to CPAP A Randomized Trial

期刊

CHEST
卷 159, 期 4, 页码 1598-1609

出版社

ELSEVIER
DOI: 10.1016/j.chest.2020.09.281

关键词

CPAP; OSA; pitolisant; residual excessive daytime sleepiness

资金

  1. Bioprojet, Paris, France

向作者/读者索取更多资源

In individuals with moderate to severe OSA adhering to CPAP treatment but experiencing residual EDS, Pitolisant significantly reduced daytime sleepiness and improved participant-reported outcomes and physician-reported disease severity. Adverse events, mainly headache and insomnia, were higher with Pitolisant compared to placebo, but no significant safety concerns were reported.
BACKGROUND: Excessive daytime sleepiness (EDS) in individuals with OSA syndrome persisting despite good adherence to CPAP is a disabling condition. Pitolisant is a selective histamine H3-receptor antagonist with wake-promoting effects. RESEARCH QUESTION: Is pitolisant effective and safe for reducing daytime sleepiness in individuals with moderate to severe OSA adhering to CPAP treatment but experiencing residual EDS? STUDY DESIGN AND METHODS: In a multicenter, double-blind, randomized (3:1), placebo-controlled, parallel-design trial, pitolisant was titrated individually at up to 20 mg/day and taken over 12 weeks. The primary end point was change in the Epworth Sleepiness Scale (ESS) score in the intention-to treat population. Key secondary end points were maintenance of wakefulness assessed by the Oxford Sleep Resistance Test, Clinical Global Impressions scale of severity, the patient's global opinion, EuroQoL quality-of-life questionnaire score, Pichot fatigue questionnaire score, and safety. RESULTS: Two hundred forty-four OSA participants (82.8% men; mean age, 53.1 years; mean Apnea Hypopnea Index with CPAP, 4.2/h; baseline ESS score, 14.7) were randomized to pitolisant (n = 183) or placebo (n = 61). ESS significantly decreased with pitolisant compared with placebo (-2.6; 95% CI, -3.9 to -1.4; P < .001), and the rate of responders to therapy (ESS # 10 or change in ESS $ 3) was significantly higher with pitolisant (71.0% vs 54.1%; P = .013). Adverse event occurrence (mainly headache and insomnia) was higher in the pitolisant group compared with the placebo group (47.0% and 32.8%, respectively; P = .03). No cardiovascular or other significant safety concerns were reported. INTERPRETATION: Pitolisant used as adjunct to CPAP therapy for OSA with residual sleepiness despite good CPAP adherence significantly reduced subjective and objective sleepiness and improved participant-reported outcomes and physician-reported disease severity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据