4.8 Article

Nanozyme-Activated Synergistic Amplification for Ultrasensitive Photoelectrochemical Immunoassay

期刊

ANALYTICAL CHEMISTRY
卷 93, 期 17, 页码 6881-6888

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c01217

关键词

-

资金

  1. National Natural Science Foundation of China [22074049, 22004042]
  2. Natural Science Foundation of Hubei Province [2020CFB276]
  3. self-determined research funds of CCNU from the colleges' basic research and operation of MOE [CCNU20QN007, CCNU20TS013]
  4. Program of Introducing Talents of Discipline to Universities of China (111 program) [B17019]

向作者/读者索取更多资源

In this study, PdPt bimetallic nanozymes were used as efficient alternatives to natural enzymes in photoelectrochemical biosensing systems, leading to amplified signals and enhanced performance. By modifying photoactive CdS nanorods with PdPt bimetallic nanozymes, a sensitive PEC immunoassay for CEA detection was successfully constructed, achieving a wider linear range and lower detection limit. This research demonstrates the potential of using nanozymes for developing ultrasensitive PEC biosensors, with improved performance and signal amplification.
At present, enzyme-mediated signal amplification strategies have been widely applied in photoelectrochemical (PEC) biosensing systems, while the introduction of natural enzymes onto the surface of photoelectrodes inevitably obstructs the electron transfer due to their insulating properties as proteins, leading to severe damage to photocurrent. In this work, the PdPt bimetallic nanozymes with the efficient peroxidase-like activity were used as alternatives to natural enzymes and amplified PEC biosensing signals via their efficient enzymatic reaction and remarkable enhancement in photocurrent. As a result, photoactive CdS nanorods modified with PdPt bimetallic nanozymes showed a boosted PEC performance compared with the pristine CdS nanorods due to the localized surface plasmon resonance effect and Schottky junction. On the basis of the as-prepared CdS/PdPt photoelectrode, a sensitive split-type glucose oxidase-mediated PEC immunoassay for carcinoembryonic antigen (CEA) detection was successfully constructed. Along with the sandwich immunocomplexing, the subsequently produced hydrogen peroxide (H2O2) can oxidize 4-chloro-1-naphthol into insoluble precipitates to inhibit photocurrent and simultaneously trigger the bio-etching of CdS to further restrain photocurrent signals due to the excellent peroxidase-mimicking activity of PdPt nanozymes. Owing to the synergistic signal amplification fulfilled by PdPt nanozymes, an ultrasensitive immunoassay of CEA was realized with a wider linear range from 1 to 5000 pg/mL and a low detection limit of 0.21 pg/mL, opening a new avenue for building ultrasensitive PEC biosensors with nanozymes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据