Clustering and Nonclustering Modifier Mixtures in Differential Mobility Spectrometry for Multidimensional Liquid Chromatography Ion Mobility-Mass Spectrometry Analysis

期刊

ANALYTICAL CHEMISTRY
卷 93, 期 17, 页码 6638-6645

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.0c04889

关键词

-

资金

  1. Swiss National Science Foundation [200021_192306]
  2. Swiss National Science Foundation (SNF) [200021_192306] Funding Source: Swiss National Science Foundation (SNF)

向作者/读者索取更多资源

Modifiers play a crucial role in tuning separation in DMS, with different types of modifier mixtures affecting resolution, selectivity, and sensitivity.
Modifiers provide fast and reliable tuning of separation in differential mobility spectrometry (DMS). DMS selectivity for separating isomeric molecules depends on the clustering modifier concentration, which is typically 1.5-3 mol % ratio of isopropanol or ethanol in nitrogen. Low concentrations (0.1%) of isopropanol were found to improve resolution and sensitivity but at the cost of practicality and robustness. Replacing the single-channel DMS pump with a binary high-performance liquid chromatography (HPLC) pump enabled the generation of modifier mixtures at a constant flow rate using an isocratic or gradient mode, and the analytical benefits of the system were investigated considering cyclohexane, n-hexane, or n-octane as nonclustering modifiers and isopropanol or ethanol as clustering modifiers. It was found that clustering and nonclustering modifier mixtures enable optimization of selectivity, resolution, and sensitivity for different positional isomers and diastereoisomers. Data further suggested different ion separation mechanisms depending on the modifier ratios. For 85 analytes, the absolute difference in compensation voltages (CoVs) between pure nitrogen and cyclohexane at 1.5 mol % ratio was below 4 V, demonstrating its potential as a nonclustering modifier. Cyclohexane's nonclustering behavior was further supported by molecular modeling using density functional theory (DFT) and calculated cluster binding energies, showing positive Delta G values. The ability to control analyte CoVs by adjusting modifier concentrations in isocratic and gradient modes is beneficial for optimizing multidimensional LCxDMS-MS. It is fast and effective for manipulating the DMS scanning window size to realize shorter mass spectrometry (MS) acquisition cycle times while maintaining a sufficient number of CoV steps and without compromising DMS separation performance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据