4.7 Article

Facile imprinted polymer for label-free highly selective potentiometric sensing of proteins: case of recombinant human erythropoietin

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 413, 期 14, 页码 3611-3623

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-021-03325-4

关键词

Recombinant human erythropoietin; Label-free sensor; Ion selective electrode; Artificial antibody; Molecularly imprinted electrode; Potentiometric sensor

向作者/读者索取更多资源

A molecularly imprinted polymer (MIP)-based potentiometric sensor was developed for label-free determination of recombinant human erythropoietin (rhEPO) in the current study. The sensor demonstrated specificity for rhEPO and could be used for the determination of rhEPO in various biopharmaceutical formulations.
In the current study, a molecularly imprinted polymer (MIP)-based potentiometric sensor was fabricated for a label-free determination of recombinant human erythropoietin (rhEPO). The MIP sensor was operated under zero current conditions using tetra-butyl ammonium bromide as a marker ion. A highly ordered rhEPO surface imprinted layer was prepared using 3-aminopropyl triethoxysilane and tetraethoxysilane as a monomer and cross-linker, respectively, under mild reaction conditions. A two-fold increase in the signal output was obtained by polymeric surface minimization (0.5 mm) that allowed more pronounced molecular recognition (imprinting factor = 20.1). The proportion of cross-reactivity was examined using different interfering biomolecules. Results confirmed sensor specificity for both structurally related and unrelated proteins. An similar to 40% decrease in the response was obtained for rhEPO-beta compared to rhEPO-alpha. The imprinted polymeric surface was evaluated using scanning electron microscopy and Fourier transform infrared spectroscopy. Under the optimal measurement conditions, a linear range of 10.00-1000.00 ng mL(-1) (10(-10) - 10(-8) M) was obtained. The sensor was employed for the determination of rhEPO in different biopharmaceutical formulations. Results were validated against standard immunoassay. Spiked human serum samples were analyzed and the assay was validated. The presence of non-specific proteins did not significantly affect (similar to 8%) the results of our assay. A concentration-dependent linear response was produced in an identical range with detection limit as low as 6.50 ng mL(-1) (2.14 x 10(-10) M). The facile fabricated MIP sensor offers a cost-effective, portable, and easy to use alternative for biosimilarity assessment and clinical application.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据