4.7 Article

Rapid and regenerable surface plasmon resonance determinations of biomarker concentration and biomolecular interaction based on tris-nitrilotriacetic acid chips

期刊

ANALYTICA CHIMICA ACTA
卷 1170, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.aca.2021.338625

关键词

Surface plasmon resonance; His-tagged protein; Tris-NTA chip; Concentration determination; Antibody-antigen interaction

资金

  1. Nature Science Foundation of China [21906065, 21802051]
  2. Natural Science Foundation of Shandong Province of China [ZR2019QB007]
  3. Shandong Provincial Program of Talent-Leading Teams

向作者/读者索取更多资源

The tris-NTA chip shows strong retention and uniform orientation of His-tagged proteins, enabling accurate quantification of IgG molecules and establishing optimal calibration curve construction time. The amount of immobilized His-protein is highly dependent on protein pI. The study outlines experimental parameters and procedures to expand SPR applications involving His-tagged proteins.
The tris-nitrilotriacetic acid (tris-NTA) chip has been used for surface plasmon resonance (SPR) kinetic studies involving histidine (His)-tagged proteins. However, its full potential, especially for analyte quantification in complex biological media, has not been realized due to a lack of systematic studies on the factors governing ligand immobilization, surface regeneration, and data analysis. We demonstrate that the tris-NTA chip not only retains His-tagged proteins more strongly than its mono-NTA counterpart, but also orients them more uniformly than protein molecules coupled to carboxymethylated dextran films. We accurately and rapidly quantified immunoglobulin (IgG) molecules in sera by using the initial association phase of their conjugation with His-tagged protein G densely immobilized onto the tris-NTA chip, and established criteria for selecting the optimal time for constructing the calibration curve. The method is highly reproducible (less than 2% RSD) and three orders of magnitude more sensitive than immunoturbidimetry. In addition, we found that the amount of His-protein immobilized is highly dependent on the protein isoelectric point (pI). Reliable kinetic data in a multi-channel SPR instrument can also be rapidly obtained by using a low density of immobilized His-tagged protein. The experimental parameters and procedures outlined in this study help expand the range of SPR applications involving His-tagged proteins. (c) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据