4.6 Article

Anatomic and Biomechanical Properties of Flat Medial Patellofemoral Ligament Reconstruction Using an Adductor Magnus Tendon Graft: A Human Cadaveric Study

期刊

AMERICAN JOURNAL OF SPORTS MEDICINE
卷 49, 期 7, 页码 1827-1838

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/03635465211009540

关键词

knee ligament; patella; anatomy; biomechanics; adductor tendon; MPFL

向作者/读者索取更多资源

This article introduces a technique for reconstructing the medial patellofemoral ligament using the adductor magnus muscle tendon and evaluates its feasibility and advantages through experimental research. The study results suggest that the adductor tendon may serve as a potential option for medial patellofemoral ligament reconstruction.
Background: In contrast to the majority of existing techniques for reconstruction of the medial patellofemoral ligament (MPFL), the technique described in this article uses the adductor magnus muscle tendon to gain a flat, broad graft, leaving its distal femoral insertion intact, and does not require drilling within or near the femoral physis. It also allows for soft tissue patellar fixation and could facilitate anatomic MPFL reconstruction in skeletally immature patients. Purpose: To evaluate the anatomic and structural properties of the native MPFL and the adductor tendon (AT), followed by biomechanical evaluation of the proposed reconstruction. Study Design: Descriptive laboratory study. Methods: The morphological and topographical features of the AT and MPFL were evaluated in 12 fresh-frozen cadaveric knees. The distance between the distal insertion of the AT on the adductor tubercle and the adductor hiatus, as well as the desired length of the graft, was measured to evaluate this graft's application potential. Load-to-failure tests were performed to determine the biomechanical properties of the proposed reconstruction construct. The construct was placed in a uniaxial testing machine and cyclically loaded 500 times between 5 and 50 N, followed by load to failure, to measure the maximum elongation, stiffness, and maximum load. Results: The mean +/- SD length of the AT was 12.6 +/- 1.5 cm, and the mean distance between the insertion on the adductor tubercle and adductor hiatus was 10.8 +/- 1.3 cm, exceeding the mean desired length of the graft (7.5 +/- 0.5 cm) by 3.3 +/- 0.7 cm. The distal insertion of the AT was slightly proximal and posterior to the insertion of the MPFL. The maximum elongation after cyclical loading was 1.9 +/- 0.4 mm. Ultimately, the mean stiffness and load to failure were 26.2 +/- 7.6 N/mm and 169.7 +/- 19.2 N, respectively. The AT graft failed at patellar fixation in 2 of the initially tested specimens and at the femoral insertion in the remaining 10. Conclusion: The described reconstruction using the AT has potential for MPFL reconstruction. The AT graft presents a graft of significant volume, beneficial anatomic topography, and adequate tensile properties in comparison with the native MPFL following the data from previously published studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据