Comparison of the performance of aerosol sampling devices for measuring infectious SARS-CoV-2 aerosols

期刊

AEROSOL SCIENCE AND TECHNOLOGY
卷 55, 期 8, 页码 975-986

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/02786826.2021.1910137

关键词

Tiina Reponen

资金

  1. Department of Homeland Security (DHS) Science and Technology (ST) Directorate [HSHQDC-15-C-00064]

向作者/读者索取更多资源

This study compared the performance of eight common low-flow aerosol sampling devices for the collection and preservation of infectious SARS-CoV-2 in small particle aerosols. Most samplers measured similar concentrations of infectious SARS-CoV-2, except for the midget impingers which measured significantly lower concentrations. Furthermore, additional clean airflow through three of the four impingers following collection of infectious virus led to a decrease in the concentration of virus over time, indicating potential inactivation of the virus and unsuitability for long duration sampling.
To assess the risk of aerosol transmission of SARS-CoV-2, measurements of the airborne viral concentrations in proximity to infected individuals, the persistence of the virus in aerosols, and the dose of the virus needed to cause infection following inhalation are required. For studies aimed at quantifying these parameters, an aerosol sampling device needs to be employed. A number of recent studies have reported the detection of both genetic material and infectious SARS-CoV-2 virus in air samples collected in clinical settings. Previous studies have demonstrated that the efficiency of different samplers for collection and preservation of the infectivity of microorganisms can vary as a function of the specific microorganism. In the present study, the performance of eight common low-flow aerosol sampling devices were compared for their ability to collect and preserve the infectivity of airborne SARS-CoV-2 contained in small particle aerosols. The influence of sampling duration on recovery of infectious virus was also evaluated. Similar concentrations of infectious SARS-CoV-2 were measured in aerosols for the majority of the samplers tested, with the exception of the midget impingers, which measured significantly lower concentrations of SARS-CoV-2. Additionally, in three of the four impingers tested, additional clean airflow through the device following collection of infectious virus resulted in a decrease of the infectious concentration of virus over time, suggesting that virus was being inactivated and these devices may not be suitable for sampling for long durations. Further, RNA copies in the samples over time did not correspond with the losses of infectious SARS-CoV-2 observed in the impingers samples. These data can be utilized to inform interpretation of current studies on the SARS-CoV-2 viral loads in air samples, as well as inform sampling device selection in future studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据