4.7 Article

Aquatic passive sampling of perfluorinated chemicals with polar organic chemical integrative sampler and environmental factors affecting sampling rate

期刊

ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH
卷 23, 期 16, 页码 16096-16103

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s11356-016-6791-1

关键词

POCIS; Sampling rate; Perfluorinated chemical; Dissolved organic matter

资金

  1. National Natural Science Foundation of China [51479067, 51209068]

向作者/读者索取更多资源

A modified polar organic chemical integrative sampler (POCIS) could provide a convenient way of monitoring perfluorinated chemicals (PFCs) in water. In the present study, the modified POCIS was calibrated to monitor PFCs. The effects of water temperature, pH, and dissolved organic matter (DOM) on the sampling rate (R (s)) of PFCs were evaluated with a static renewal system. During laboratory validation over a 14-day period, the uptake kinetics of PFCs was linear with the POCIS. DOM and water temperature slightly influenced POCIS uptake rates, which is in consistent with the theory for uptake into POCIS. Therefore, within a narrow span of DOM and water temperatures, it was unnecessary to adjust the R (s) value for POCIS. Laboratory experiments were conducted with water over pH ranges of 3, 7, and 9. The R (s) values declined significantly with pH increase for PFCs. Although pH affected the uptake of PFCs, the effect was less than twofold. Application of the R (s) value to analyze PFCs with POCIS deployed in the field provided similar concentrations obtained from grab samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据