The study showed that AP-LS has high specificity and low sensitivity in detecting spinal injuries, with the highest sensitivity observed for thoracic spinal injuries. There was low interrater reliability among observers, and potentially unstable spinal injuries were more likely to be detected than stable injuries.
Background Spinal injuries are present in 16-31% of polytraumatized patients. Rapid identification of spinal injuries requiring immobilization or operative treatment is essential. The Lodox-Statscan (LS) has evolved into a promising time-saving diagnostic tool to diagnose life-threatening injuries with an anterior-posterior (AP)-full-body digital X-ray. Methods We aimed to analyze the diagnostic accuracy and the interrater reliability of AP-LS to detect spinal injuries in polytraumatized patients. Therefore, within 3 years, AP-LS of polytraumatized patients (ISS >= 16) were retrospectively analyzed by three independent observers. The sensitivity and specificity of correct diagnosis with AP-LS compared to CT scan were calculated. The diagnostic accuracy was evaluated by using the area under the ROC (receiver operating characteristic curve) for sensitivity and specificity. Interrater reliability between the three observers was calculated using Fleiss' Kappa. The sensitivity of AP-LS was further analyzed by the severity of spinal injuries. Results The study group included 320 patients (48.5 years +/- 19.5, 89 women). On CT scan, 207 patients presented with a spinal injury (65%, total of 332 injuries). AP-LS had a low sensitivity of 9% (31 of 332, range 0-24%) and high specificity of 99% (range 98-100%). The sensitivity was highest for thoracic spinal injuries (14%). The interrater reliability was slight (kappa = 0.02; 95% CI: 0.00, 0.03). Potentially unstable spinal injuries were more likely to be detected than stable injuries (sensitivity 18 and 6%, respectively). Conclusion This study demonstrated high specificity with low sensitivity of AP-LS in detecting spinal injuries compared to CT scan. In polytraumatized patients, AP-LS, implemented in the Advanced Trauma Life Support-algorithm, is a helpful tool to diagnose life-threatening injuries. However, if spinal injuries are suspected, performing a full-body CT scan is necessary for correct diagnosis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据