4.6 Article

Possibility of Combining Carbon Dots and Liquid Exfoliated Graphene as a Carbon-Based Light Addressable Potentiometric Sensor

期刊

ACS SENSORS
卷 6, 期 3, 页码 1218-1227

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acssensors.0c02515

关键词

light addressable potentiometric sensor; carbon dot; liquid exfoliated graphene; photogenerated carrier; built-in electric field; immune reaction

资金

  1. National Natural Science Foundation of China [61771260]

向作者/读者索取更多资源

This study presents a carbon-based light addressable potentiometric sensor (C-LAPS) using a combination of carbon dots (CDs) and liquid exfoliated graphene (LEG). The electronic and photoelectronic features of C-LAPS are measured and compared with electrodes decorated with pure CDs and LEG. The feasibility for biological application is justified using an immune reaction as a proof of concept, showing improved linear responses compared to traditional semiconductor-based LAPS.
A light addressable potentiometric sensor (LAPS) is a versatile sensing platform for bioassay. However, the lack of carbon-based LAPS (C-LAPS) is a bottleneck for its sustainable development in a carbon electronic era. Herein, a study of C-LAPS based on the combinations of carbon dots (CDs) and liquid exfoliated graphene (LEG) is presented. Devices of C-LAPS are first fabricated by self-assembling the hydrothermally synthesized CDs and the cosolvent ultrasonic delaminated LEG on poly(diallyldimethylammonium chloride) (PDDA)-modified indium tin oxide (ITO) glasses. According to the stacking orders of CDs and LEG, CLAPS are named as CDs/LEG@PDDA/ITO and LEG/CDs@PDDA/ITO. Then, their electronic and photoelectronic features are measured and compared with the pure CD- and pure LEG-decorated ITO electrodes. Furthermore, working mechanisms are proposed by means of the classical theories of energy band bending and built-in electric field at the heterojunction of CDs and LEG. The resemblances of CDs/LEG@PDDA/ITO-based C-LAPS with Si-based LAPS (Si-LAPS) are confirmed from the points of view of production and separation of the photogenerated carriers, the formation of photocurrent, and the distinction with LEG/CDs@PDDA/ITO. Finally, its feasibility for biological application is justified by using the immune reaction of 5-methylcytosine (5mC) and its antibody (anti-5mC) as a proof of concept. The improved linear responses are evidenced by the comparisons with Si-LAPS' results. Conclusively, the proposed C-LAPS is believed to be a candidate for traditional semiconductor-based LAPS, with the merit of solutionprocessable. Meanwhile, the theoretical deductions about C-LAPS' principle can also pave the way for developing similar carbonbased sensors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据