4.6 Article

Experimental Study on Delaying the Failure Time of In-Service Cables in Trays by Using Fire-Retardant Coatings

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Engineering, Civil

Experimental investigation on maximum ceiling jet temperature generated by a vertically spreading cable fire

Xianjia Huang et al.

Summary: The study demonstrates that in vertical cable tray fires, the upward spreading of cable flames can affect the characteristics of MCJT, resulting in temperature increase. Through experiments and model adjustments, effective estimation of MCJT can be achieved.

FIRE SAFETY JOURNAL (2021)

Article Thermodynamics

The effects causing the burning of plastic coatings of fire-resistant cables and its consequences

Zsuzsanna Kerekes et al.

JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY (2020)

Review Construction & Building Technology

Fire Performance of Structural Cables: Current Understanding, Knowledge Gaps, and Proposed Research Agenda

Panagiotis Kotsovinos et al.

JOURNAL OF STRUCTURAL ENGINEERING (2020)

Article Construction & Building Technology

Study on temperature distribution and CO diffusion induced by cable fire in L-shaped utility tunnel

Weiguang An et al.

SUSTAINABLE CITIES AND SOCIETY (2020)

Article Chemistry, Applied

The study of adhesion between steel substrate, primer, and char of intumescent fire retardant coating

W. C. Puspitasari et al.

PROGRESS IN ORGANIC COATINGS (2019)

Review Construction & Building Technology

Intumescent coatings used for the fire-safe design of steel structures: A review

Andrea Lucherini et al.

JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH (2019)

Article Thermodynamics

Study on cable fire spread and smoke temperature distribution in T-shaped utility tunnel

Kai Liang et al.

CASE STUDIES IN THERMAL ENGINEERING (2019)

Review Chemistry, Applied

Intumescent coatings: A review on recent progress

Ravindra G. Puri et al.

JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH (2017)

Review Engineering, Multidisciplinary

Recent developments of intumescent fire protection coatings for structural steel: A review

Thirumal Mariappan

JOURNAL OF FIRE SCIENCES (2016)

Proceedings Paper Engineering, Multidisciplinary

The Study of the Cable Failure Criteria Used in Fire PSA

Yi-chen Yang et al.

2015 INTERNATIONAL CONFERENCE ON PERFORMANCE-BASED FIRE AND FIRE PROTECTION ENGINEERING (ICPFFPE 2015) (2016)

Article Engineering, Mechanical

The protective effect of a fire-retardant coating on the insulation failure of PVC cable

Ji Wang et al.

ENGINEERING FAILURE ANALYSIS (2013)

Article Polymer Science

Flame retarded Thermoplastic Polyurethane (TPU) for cable jacketing application

D. Tabuani et al.

POLYMER DEGRADATION AND STABILITY (2012)

Proceedings Paper Economics

Simulation Study on Value of Cable Fire in the Cable Tunnel

Yingjian Niu et al.

INTERNATIONAL SYMPOSIUM ON SAFETY SCIENCE AND ENGINEERING IN CHINA, 2012 (2012)