4.5 Review

Systematic review on use, cost and clinical efficacy of automated decontamination devices

出版社

BMC
DOI: 10.1186/s13756-021-00894-y

关键词

Decontamination; Environment; Hospital-acquired infection; Ultraviolet light; Hydrogen peroxide; Toxicity; Cost

资金

  1. NHS Lanarkshire Research Development
  2. School of Applied Sciences, Edinburgh Napier University, Scotland

向作者/读者索取更多资源

The systematic review on automated devices using H202 or UV for surface decontamination showed mixed results on patient benefit. Most non-outbreak studies lacked appropriate control groups and were potentially compromised by industry sponsorship. Routine use of these devices requires justification from standardized and controlled studies to understand the best way to manage contaminated healthcare environments.
BackgroundMore evidence is emerging on the role of surface decontamination for reducing hospital-acquired infection (HAI). Timely and adequate removal of environmental pathogens leads to measurable clinical benefit in both routine and outbreak situations.ObjectivesThis systematic review aimed to evaluate published studies describing the effect of automated technologies delivering hydrogen peroxide (H202) or ultra-violet (UV) light on HAI rates.MethodsA systematic review was performed using relevant search terms. Databases were scanned from January 2005 to March 2020 for studies reporting clinical outcome after use of automated devices on healthcare surfaces. Information collected included device type, overall findings; hospital and ward data; study location, length and size; antimicrobial consumption; domestic monitoring; and infection control interventions. Study sponsorship and duplicate publications were also noted.ResultsWhile there are clear benefits from non-touch devices in vitro, we found insufficient objective assessment of patient outcome due to the before-and-after nature of 36 of 43 (84%) studies. Of 43 studies, 20 (47%) used hydrogen peroxide (14 for outbreaks) and 23 (53%) used UV technology (none for outbreaks). The most popular pathogen targeted, either alone or in combination with others, was Clostridium difficile (27 of 43 studies: 63%), followed by methicillin-resistant Staphylococcus aureus (MRSA) (16 of 43: 37%). Many owed funding and/or personnel to industry sponsorship (28 of 43: 65%) and most were confounded by concurrent infection control, antimicrobial stewardship and/or cleaning audit initiatives. Few contained data on device costs and rarely on comparable costs (1 of 43: 2%). There were expected relationships between the country hosting the study and location of device companies. None mentioned the potential for environmental damage, including effects on microbial survivors.ConclusionThere were mixed results for patient benefit from this review of automated devices using H202 or UV for surface decontamination. Most non-outbreak studies lacked an appropriate control group and were potentially compromised by industry sponsorship. Concern over HAI encourages delivery of powerful disinfectants for eliminating pathogens without appreciating toxicity or cost benefit. Routine use of these devices requires justification from standardized and controlled studies to understand how best to manage contaminated healthcare environments.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据