4.8 Article

Reaching Deeper: Absolute In Vivo Thermal Reading of Liver by Combining Superbright Ag2S Nanothermometers and In Silico Simulations

期刊

ADVANCED SCIENCE
卷 8, 期 9, 页码 -

出版社

WILEY
DOI: 10.1002/advs.202003838

关键词

deep tissue; liver; luminescence; nanoparticles; nano‐ thermometry

资金

  1. Spanish Ministry of Economy and Competitiveness [MAT2016-75362-C3-1-R, MAT2017-83111R, MAT2017-85617-R]
  2. Instituto de Salud Carlos III [PI16/00812]
  3. Comunidad Autonoma de Madrid [B2017/BMD-3867]
  4. European Structural and investment fund
  5. European Union's Horizon 2020 FET Open programme [801305]
  6. Fundacion para la Investigacion Biomedica del Hospital Universitario Ramon y Cajal project [IMP18_38 (2018/0265)]
  7. COST action [CA17140]
  8. China Scholarship Council [201806870023]
  9. UCM-Santander [CT63/19-CT64/19]
  10. Community of Madrid [PEJD-2017-PRE/IND-3663]
  11. Spanish Ministry of Science and Innovation through the Ramon y Cajal [RYC2018-025253-I]
  12. Ministry of Economy and Competitiveness [MAT2017-85617-R, MAT2017-88148R, RED2018-102626-T, PID2019-106211RB-I00]
  13. Severo Ochoa Program for Centers of Excellence in RD [SEV-2016-0686]
  14. NoCanTher project from the European Union's Horizon 2020 research and innovation programme [685795]
  15. [FJC2018-036734-I]

向作者/读者索取更多资源

Luminescent nano-thermometry has great potential for in vivo sensing, diagnosis, and therapy, but faces limitations due to tissue attenuation and accuracy issues. This study demonstrates the use of high-brightness Ag2S nanothermometers for reliable and absolute internal organ thermal sensing, through a combination of in vivo and in silico measurements to assess hyperthermia processes and nanoparticle contribution to heating.
Luminescent nano-thermometry is a fast-developing technique with great potential for in vivo sensing, diagnosis, and therapy. Unfortunately, it presents serious limitations. The luminescence generated by nanothermometers, from which thermal readout is obtained, is strongly distorted by the attenuation induced by tissues. Such distortions lead to low signal levels and entangle absolute and reliable thermal monitoring of internal organs. Overcoming both limitations requires the use of high-brightness luminescent nanothermometers and adopting more complex approaches for temperature estimation. In this work, it is demonstrated how superbright Ag2S nanothermometers can provide in vivo, reliable, and absolute thermal reading of the liver during laser-induced hyperthermia. For that, a new procedure is designed in which thermal readout is obtained from the combination of in vivo transient thermometry measurements and in silico simulations. The synergy between in vivo and in silico measurements has made it possible to assess relevant numbers such as the efficiency of hyperthermia processes, the total heat energy deposited in the liver, and the relative contribution of Ag2S nanoparticles to liver heating. This work provides a new way for absolute thermal sensing of internal organs with potential application not only to hyperthermia processes but also to advanced diagnosis and therapy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据