4.7 Article

Basalt Fibre Composite with Carbon Nanomodified Epoxy Matrix under Hydrothermal Ageing

期刊

POLYMERS
卷 13, 期 4, 页码 -

出版社

MDPI
DOI: 10.3390/polym13040532

关键词

polymer composite; carbon nanofiller; epoxy; hydrothermal ageing; mechanical properties; water absorption; electrical resistance

资金

  1. ERDF project [1.1.1.2/VIAA/1/16/066]
  2. M-Era project [1.1.1.5/ERANET/18/02]
  3. Latvian State Education Development Agency [1.1.1.5/ERANET/18/02]

向作者/读者索取更多资源

The study investigated the effect of hybrid carbon nanofillers on the electrical and flexural properties for an epoxy matrix and basalt fiber reinforcing composite subjected to seasonal water absorption. Results showed minimal changes in mechanical properties after environmental ageing. Nanomodified BFRCs exhibited slightly higher effects on flexural characteristics due to higher defectiveness. Nanocomposites showed higher electrical conductivity, with UD BFRC/NC showing significantly improved conductivity after hydrothermal ageing, enhancing damage monitoring capabilities.
This work aimed to investigate the effect of hybrid carbon nanofillers (e.g., carbon nanotubes/carbon nanofibers in the ratio 1:1 by mass) over the electrical and flexural properties for an epoxy matrix and corresponding basalt fibre reinforcing composite (BFRC) subjected to full-year seasonal water absorption. Hydrothermal ageing was performed by full immersion of the tested materials into distilled water according to the following model conditions (seasons). The mechanical properties were measured in three-point bending mode before environmental ageing and after each season. Upon environmental ageing, the relative change of flexural strength and elastic modulus of the epoxy and NC was within 10-15%. For nanomodified BFRCs, the slightly higher effect (approx. by 10%) of absorbed moisture on flexural characteristics was found and likely attributed to higher defectiveness (e.g., porosity, the formation of agglomerates etc.). During flexural tests, electrical resistance of the nanocomposites (NC) and BFRC/NC samples was evaluated. The electrical conductivity for UD BFRC/NC, before and after hydrothermal ageing, was by 2 and 3 times higher than for the NC, accordingly, revealing the orientation of electrically conductive nanoparticles and/or their agglomerates during lay-up manufacturing which was evaluated by the rules of the mixture. Based on all results obtained it can be concluded that the most potentially applicable for damage indication was UD BFRC/NC along fibres since full-year hydrothermal ageing improved its electrical conductivity by approx. 98% and, consequently, the ability to monitor damages was also enhanced.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据