相关参考文献
注意:仅列出部分参考文献,下载原文获取全部文献信息。Pushing Cherenkov PET with BGO via coincidence time resolution classification and correction
Nicolaus Kratochwil et al.
PHYSICS IN MEDICINE AND BIOLOGY (2020)
Roadmap toward the 10 ps time-of-flight PET challenge
Paul Lecoq et al.
PHYSICS IN MEDICINE AND BIOLOGY (2020)
Experimental time resolution limits of modern SiPMs and TOF-PET detectors exploring different scintillators and Cherenkov emission
Stefan Gundacker et al.
PHYSICS IN MEDICINE AND BIOLOGY (2020)
Electronics method to advance the coincidence time resolution with bismuth germanate
Joshua W. Cates et al.
PHYSICS IN MEDICINE AND BIOLOGY (2019)
Understanding and simulating SiPMs
Fabio Acerbi et al.
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2019)
Medical applications of silicon photomultipliers
Maria Giuseppina Bisogni et al.
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2019)
Overview on the main parameters and technology of modern Silicon Photomultipliers
Claudio Piemonte et al.
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2019)
High-frequency SiPM readout advances measured coincidence time resolution limits in TOF-PET
Stefan Gundacker et al.
PHYSICS IN MEDICINE AND BIOLOGY (2019)
The new opportunities for high time resolution clinical TOF PET
Maurizio Conti et al.
CLINICAL AND TRANSLATIONAL IMAGING (2019)
Approximations of coincidence time resolution models of scintillator detectors with leading edge discriminator
S. Vinogradov
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2018)
Single photon time resolution of state of the art SiPMs
M. V. Nemallapudi et al.
JOURNAL OF INSTRUMENTATION (2016)
State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMs
S. Gundacker et al.
JOURNAL OF INSTRUMENTATION (2016)
NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system
Alexander M. Grant et al.
MEDICAL PHYSICS (2016)
Advances in digital SiPMs and their application in biomedical imaging
Dennis R. Schaart et al.
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2016)
Advances in time-of-flight PET
Suleman Surti et al.
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2016)
Advances in coincidence time resolution for PET
Joshua W. Cates et al.
PHYSICS IN MEDICINE AND BIOLOGY (2016)
A Digital Preclinical PET/MRI Insert and Initial Results
Bjoern Weissler et al.
IEEE TRANSACTIONS ON MEDICAL IMAGING (2015)
Improvement in PET/CT image quality in overweight patients with PSF and TOF
Takafumi Taniguchi et al.
ANNALS OF NUCLEAR MEDICINE (2015)
Development of ClearPEM-Sonic, a multimodal mammography system for PET and Ultrasound
G. Cucciati et al.
JOURNAL OF INSTRUMENTATION (2014)
Time resolution deterioration with increasing crystal length in a TOF-PET system
S. Gundacker et al.
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2014)
SiPM optical crosstalk amplification due to scintillator crystal: effects on timing performance
Alberto Gola et al.
PHYSICS IN MEDICINE AND BIOLOGY (2014)
Estimating Image Quality for Future Generations of TOF PET Scanners
Maurizio Conti et al.
IEEE TRANSACTIONS ON NUCLEAR SCIENCE (2013)
Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: an experimental and theoretical analysis
S. Gundacker et al.
JOURNAL OF INSTRUMENTATION (2013)
A prototype MR insertable brain PET using tileable GAPD arrays
Key Jo Hong et al.
MEDICAL PHYSICS (2013)
A Comprehensive Model to Predict the Timing Resolution of SiPM-Based Scintillation Detectors: Theory and Experimental Validation
Stefan Seifert et al.
IEEE TRANSACTIONS ON NUCLEAR SCIENCE (2012)
Time-Based Readout of a Silicon Photomultiplier (SiPM) for Time of Flight Positron Emission Tomography (TOF-PET)
F. Powolny et al.
IEEE TRANSACTIONS ON NUCLEAR SCIENCE (2011)
An outlook on future design of hybrid PET/MRI systems
Habib Zaidi et al.
MEDICAL PHYSICS (2011)
Why is TOF PET reconstruction a more robust method in the presence of inconsistent data?
Maurizio Conti
PHYSICS IN MEDICINE AND BIOLOGY (2011)
On the efficiency of photon emission during electrical breakdown in silicon
A. Nepomuk Otte
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2009)
Optimizing the timing resolution of SiPM sensors for use in TOF-PET detectors
R. Vinke et al.
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2009)
Hamamatsu APD for CMS ECAL: quality insurance
D Bailleux et al.
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2004)
Clear-PEM, a dedicated PET camera for mammography
P Lecoq et al.
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2002)
Properties of the avalanche photodiodes for the CMS electromagnetic calorimeter
K Deiters et al.
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2000)
Limited Geiger-mode microcell silicon photodiode: new results
G Bondarenko et al.
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2000)