4.6 Article

ML-SIM: universal reconstruction of structured illumination microscopy images using transfer learning

期刊

BIOMEDICAL OPTICS EXPRESS
卷 12, 期 5, 页码 2720-2733

出版社

Optica Publishing Group
DOI: 10.1364/BOE.414680

关键词

-

资金

  1. Engineering and Physical Sciences Research Council [L015889]
  2. Wellcome Trust [089703]
  3. Medical Research Council [K015850]

向作者/读者索取更多资源

ML-SIM is a versatile reconstruction method that utilizes transfer learning to obtain a parameter-free model with generalizability and robustness. Trained on simulated images to reflect challenging imaging conditions, it does not require experimental data and can be adapted efficiently to any specific experimental SIM implementation. Its reconstruction of a SIM stack in less than 200 ms on a modern GPU enables real-time imaging applications, demonstrating advantages in terms of generality and noise robustness compared to current state-of-the-art SIM reconstruction methods.
Structured illumination microscopy (SIM) has become an important technique for optical super-resolution imaging because it allows a doubling of image resolution at speeds compatible with live-cell imaging. However, the reconstruction of SIM images is often slow, prone to artefacts, and requires multiple parameter adjustments to reflect different hardware or experimental conditions. Here, we introduce a versatile reconstruction method, ML-SIM, which makes use of transfer learning to obtain a parameter-free model that generalises beyond the task of reconstructing data recorded by a specific imaging system for a specific sample type. We demonstrate the generality of the model and the high quality of the obtained reconstructions by application of ML-SIM on raw data obtained for multiple sample types acquired on distinct SIM microscopes. ML-SIM is an end-to-end deep residual neural network that is trained on an auxiliary domain consisting of simulated images, but is transferable to the target task of reconstructing experimental SIM images. By generating the training data to reflect challenging imaging conditions encountered in real systems, ML-SIM becomes robust to noise and irregularities in the illumination patterns of the raw SIM input frames. Since ML-SIM does not require the acquisition of experimental training data, the method can be efficiently adapted to any specific experimental SIM implementation. We compare the reconstruction quality enabled by ML-SIM with current state-of-the-art SIM reconstruction methods and demonstrate advantages in terms of generality and robustness to noise for both simulated and experimental inputs, thus making ML-SIM a useful alternative to traditional methods for challenging imaging conditions. Additionally, reconstruction of a SIM stack is accomplished in less than 200 ms on a modern graphics processing unit, enabling future applications for real-time imaging. Source code and ready-to-use software for the method are available at http://ML-SIM.github.io.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据