4.5 Article

A multiplex real-time PCR quantitation of human herpesvirus-6, 7, 8 viruses: application in blood transfusions

期刊

VIROLOGY JOURNAL
卷 18, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12985-021-01510-6

关键词

Human herpesvirus; Pityriasis rosea; Blood transfusion; Multiplex real-time PCR

类别

向作者/读者索取更多资源

Fluorescent quantitative PCR assay is widely used for detecting viral DNA, but a new method has been developed to simultaneously detect HHV-6, 7, and 8. Through blood sample collection and PCR optimization, a triple fluorescent quantitative PCR detection system was constructed for the simultaneous detection of HHV-6, 7, and 8. The method showed good specificity and sensitivity in blood transfusion screening.
BackgroundIn recent years, fluorescent quantitative polymerase chain reaction assays for detecting viral DNA are in widespread use throughout the world. However, considering the wide distribution of new herpesvirus among the population, we constructed a method to detect HHV-6, 7, and 8 simultaneously.MethodsThe blood samples of 74 blood donors and 45 pityriasis rosea patients were collected. The recombinant plasmids containing U67, U36, and orf65 were constructed to optimize the PCR reaction system. The forward and reverse primers and probe sequences of HHV-6 were as follows: TAAATATCGATGCCGCTCTG, ACGTTCTAGCCATCTTCTTTG, CGCAAACGACAAAGCCA. The forward and reverse primers and probe sequences of HHV-7 were as follows: TTAGACATCTTACACGACAGC, CAGCTTTTCGAACTTGTCAC, TTCATCGGGTACGTCCA. The forward and reverse primers and probe sequences of HHV-8 were as follows: GCGACATATTTCCCTGATCC, CCAACTTTAAGGTGAGAGACC, CATGCGAGCCACCAG. Through the detection of housekeeping genes, DNA sequencing, and optimization of the PCR reaction system, the triple fluorescent quantitative PCR detection system was constructed. Blood samples of blood transfusion staff and pityriasis rosea patients were detected.ResultsThe correlations of HHV-6, 7, and 8 between single and multiplex PCR are 0.980, 0.987, 0.965, respectively. In 74 blood donor samples, 16.2% of HHV-6 and 55% of HHV-7 were positive (viral load>3 log10 copies/ml) according to multiplex real-time PCR. In 45 patients suspected of pityriasis rosea (PR) infection, 40% HHV-6, 73.3% positive cases are found.ConclusionWith the safety of blood transfusion being a major concern of the public, this method will show good specificity and sensitivity in blood transfusion screening.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据