4.6 Article Proceedings Paper

Thiol-grafted magnetic polymer for preconcentration of Cd, Hg, Pb from environmental water followed by inductively coupled plasma mass spectrometry detection

期刊

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.sab.2021.106071

关键词

Heavy metals; Magnetic solid phase extraction; Thiol-group modified magnetic polymer; Inductively coupled plasma mass spectrometry; Environmental waters

资金

  1. National Natural Science Foundation of China [21775113, 21974100]
  2. Science Fund for Creative Research Groups of NSFC [20921062]

向作者/读者索取更多资源

A novel thiol-grafted magnetic polymer with high sulfur content and large surface area was synthesized, showing high adsorption capacity for mercury, cadmium, and lead ions. A method combining magnetic solid phase extraction and inductively coupled plasma mass spectrometry was developed and optimized for quantification of trace heavy metals in environmental water samples, demonstrating low detection limits and good accuracy. The potential application was validated by analyzing water samples from the Yangtze River and East Lake, showing successful recoveries of target ions at various concentration levels.
A novel thiol-grafted magnetic polymer (MPPs-SH) was synthesized by click reaction between 1,2-ethanedithiol and Fe3O4@SiO2@poly (ethylene glycol dimethacrylate-co-glycidyl methacrylate). The resultant MPPs-SH had high S content (5.4 wt%) and exhibited large specific surface area (156.8 m(2) g(-1)) as well as high adsorption capacity of 254, 64.2, 56.6 mg g(-1) for mercury, cadmium and lead ions, respectively. With the prepared MPPs-SH as sorbent, a method of magnetic solid phase extraction combined with inductively coupled plasma mass spectrometry was developed for the quantification of trace mercury, cadmium and lead in environmental water samples. The extraction conditions including sample pH, sample volume, sorbent amount, adsorption/desorption time and elution volume were optimized. Under the optimal conditions, three heavy metal ions were extracted from 150 mL aqueous solution in 10 min and eluted by 0.2 mol L-1 HNO3 containing 2% thiourea in 5 min. The method presented low limits of detection (0.21, 0.82 and 2.9 ng L 1) for target ions. The accuracy of the method was validated by using Certified Reference Materials of Environmental Water including GSB 07-1185-2000 (201435), GSB 07-1183-2000 (201239) and GSB 07-3173-2014 (202046). The application potential was further validated by the determination of trace mercury, cadmium and lead in Yangtze river and East lake water samples. The content of target heavy metal ions in tested water sample was found to be in the range of 6.40-195 ng L-1, and the recoveries of 86.4-109% were obtained at three spiking concentration levels for mercury, cadmium and lead ions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据