4.2 Article

Deep learning detection of subtle fractures using staged algorithms to mimic radiologist search pattern

期刊

SKELETAL RADIOLOGY
卷 51, 期 2, 页码 345-353

出版社

SPRINGER
DOI: 10.1007/s00256-021-03739-2

关键词

Artificial intelligence; Machine learning; Neural network; Convolutional neural network; Deep convolutional neural network; Triquetral fracture; Segond fracture; Fracture detection; Fracture

向作者/读者索取更多资源

The study developed a two-stage deep convolutional neural network system that mimics a radiologist's search pattern for detecting triquetral avulsion fractures and Segond fractures. Results showed that the system achieved high accuracy in cross-validation and generalized well to external test data. Focusing attention on specific image regions appears to improve the detection accuracy of subtle findings.
Objective To develop and evaluate a two-stage deep convolutional neural network system that mimics a radiologist's search pattern for detecting two small fractures: triquetral avulsion fractures and Segond fractures. Materials and methods We obtained 231 lateral wrist radiographs and 173 anteroposterior knee radiographs from the Stanford MURA and LERA datasets and the public domain to train and validate a two-stage deep convolutional neural network system: (1) object detectors that crop the dorsal triquetrum or lateral tibial condyle, trained on control images, followed by (2) classifiers for triquetral and Segond fractures, trained on a 1:1 case:control split. A second set of classifiers was trained on uncropped images for comparison. External test sets of 50 lateral wrist radiographs and 24 anteroposterior knee radiographs were used to evaluate generalizability. Gradient-class activation mapping was used to inspect image regions of greater importance in deciding the final classification. Results The object detectors accurately cropped the regions of interest in all validation and test images. The two-stage system achieved cross-validated area under the receiver operating characteristic curve values of 0.959 and 0.989 on triquetral and Segond fractures, compared with 0.860 (p = 0.0086) and 0.909 (p = 0.0074), respectively, for a one-stage classifier. Two-stage cross-validation accuracies were 90.8% and 92.5% for triquetral and Segond fractures, respectively. Conclusion A two-stage pipeline increases accuracy in the detection of subtle fractures on radiographs compared with a one-stage classifier and generalized well to external test data. Focusing attention on specific image regions appears to improve detection of subtle findings that may otherwise be missed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据