4.7 Article

A novel acetylcholinesterase biosensor with dual-recognized strategy based on molecularly imprinted polymer

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 337, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2021.129760

关键词

Dual-recognized strategy; Acetylcholinesterase-based biosensor; Molecularly imprinted polymers; Organophosphorus pesticide; AChE inhibition assay

资金

  1. National Key R&D Program of China [2019YFA0905500]
  2. National Natural Science Foundation of China [21611130030, 21277054]
  3. Chinese CivilMilitary Integration program [BLB19J008]

向作者/读者索取更多资源

A novel dual-recognized strategy using MIP and AChE was developed to detect pesticides, providing increased selectivity and accuracy in identifying enzyme inhibitors in complex samples using enzyme-based biosensors.
Biosensors using acetylcholinesterase (AChE) as the recognition element detect both toxicity (AChE inhibition activity) and concentration of organophosphorus pesticides (OPs). However, real application of these biosensors remains a challenge due to their low selectivity and low resistance to sample matrix, interferences and hash analytical conditions. In this study, a novel dual-recognized strategy was established by using molecularly imprinted polymer (MIP) and AChE selective to different moieties of acephate (AP) as affinity molecules simultaneously. Using AP as the model OP, MIP highly selective to certain moieties but not phosphorus of AP was prepared on the surface of microplate by self-polymerization of dopamine. The MIP enriched AP from samples selectively. Then AChE selective to phosphorus of AP quantified the levels of AP captured by MIP. AP captured by MIP still inhibited the activity of AChE because the affinity of AP to AChE was higher than to MIP. By incorporating selective sample pretreatment with AChE inhibition assay in one sensor, the biosensor identified AP from other OPs, carbamates pesticides and interferences commonly found in food and environmental samples. When vegetables with high matrix effect on AChE inhibition assay were analyzed, selective sample pretreatment ensured the biosensor to detect AP more accurately and selectively than classical AChE inhibition assay. The results of the biosensor had no statistical difference compared with those of HPLC-MS/MS. The dual-recognized strategy may provide a new solution to detect target enzyme inhibitors in complicated samples using enzymebased biosensors selectively and accurately.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据