4.6 Review

Review of Wearable Sensor-Based Health Monitoring Glove Devices for Rheumatoid Arthritis

期刊

SENSORS
卷 21, 期 5, 页码 -

出版社

MDPI
DOI: 10.3390/s21051576

关键词

rheumatoid arthritis; smart sensing; data gloves; joint measurement; rehabilitation; range of motion

资金

  1. Department for the Economy (DFE), SENDocWearable Sensor Technologies (European project)

向作者/读者索取更多资源

Early detection of Rheumatoid Arthritis and other neurological conditions is crucial for effective treatment. Current methods of detection have weaknesses, and pharmaceutical treatments aim to reduce the debilitating effects of the illness. Further research and application of wearable sensing devices are needed to improve diagnosis and rehabilitation activities.
Early detection of Rheumatoid Arthritis (RA) and other neurological conditions is vital for effective treatment. Existing methods of detecting RA rely on observation, questionnaires, and physical measurement, each with their own weaknesses. Pharmaceutical medications and procedures aim to reduce the debilitating effect, preventing the progression of the illness and bringing the condition into remission. There is still a great deal of ambiguity around patient diagnosis, as the difficulty of measurement has reduced the importance that joint stiffness plays as an RA identifier. The research areas of medical rehabilitation and clinical assessment indicate high impact applications for wearable sensing devices. As a result, the overall aim of this research is to review current sensor technologies that could be used to measure an individual's RA severity. Other research teams within RA have previously developed objective measuring devices to assess the physical symptoms of hand steadiness through to joint stiffness. Unfamiliar physical effects of these sensory devices restricted their introduction into clinical practice. This paper provides an updated review among the sensor and glove types proposed in the literature to assist with the diagnosis and rehabilitation activities of RA. Consequently, the main goal of this paper is to review contact systems and to outline their potentialities and limitations. Considerable attention has been paid to gloved based devices as they have been extensively researched for medical practice in recent years. Such technologies are reviewed to determine whether they are suitable measuring tools.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据