4.6 Article

A novel investigation of the effect of different concentrations of methacrylic acid on the dose response of MAGAT gel dosimeter in intraoperative radiotherapy

期刊

RADIATION PHYSICS AND CHEMISTRY
卷 179, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.radphyschem.2020.109214

关键词

Intraoperative radiotherapy (IORT); MAGAT; Radiation dosimetry; Low dose rate; Low energy

资金

  1. Tehran University of Medical Sciences [96-03-30-36303]

向作者/读者索取更多资源

The study investigated the dose response of MAGAT gel dosimeter with varying concentrations of methacrylic acid, leading to the discovery that MAGAT with 8% MAA concentration exhibited high dose sensitivity under IORT irradiation. Additionally, the response of MAGAT was found to be independent of dose rates and energy levels.
Purpose: High dose prescription in one treatment session of intraoperative radiotherapy (IORT) requires precise monitoring of the delivered dose. Methacrylic acid, gelatin and tetrakis phosphonium chloride (MAGAT) gel with superior dose sensitivity and dose resolution seems to be a suitable tool for 3 dimensional dose verification of IORT. In the current study, the dose response of MAGAT gel dosimeter with varying concentrations of methacrylic acid (MAA) was investigated. Finally, the MAGAT with optimal concentration was subjected to dose rate and energy dependency measurements. Methods: MAGAT gel with different concentrations of 3, 5, 6, 8 and 10% was manufactured and irradiated with 50 keV produced by IORT. Gel vials were read out by MRI and R-2 responses were plotted against dose. Dose rate and energy dependency of optimum MAGAT gel were assessed by irradiation by a VARIAN linear accelerator using various dose rates of 30, 40 and 50 cGy/min and diverse photon energies of 6 and 18 MV as well as 50 keV of IORT. Results: MAGAT with a concentration of 8% MAA, exhibited a high-dose response and dose sensitivity of 5.16 Gy(-1) s(-1) in irradiation by IORT. Moreover, its response was independent of low dose rates (30, 40 and 50 cGy/min) and mega-voltage energies (p > 0.05). However, there was a significant difference between the R-2-dose response of MAGAT irradiated by mega-voltage (6 and 18 MV) and 50 keV energy of IORT. Conclusion: MAGAT is an effective tool to investigate three dimensional dose distributions of IORT independent of dose rates used in X-ray IORT. Moreover, its response is energy independent over mega-voltage energies.Y

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据