Comparison of extracellular vesicle isolation and storage methods using high-sensitivity flow cytometry

期刊

PLOS ONE
卷 16, 期 2, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0245835

关键词

-

资金

  1. Research Foundation Flanders (FWO)
  2. Flemish Institute for Technological Research (VITO) [12S6517N]
  3. FWO
  4. EU through the Interreg IV Flanders-the Netherlands project Interreg V Flanders-the Netherlands project Trans Tech Diagnostics (TTD)
  5. VITO [1S69320N]

向作者/读者索取更多资源

This study compared the yield and purity of EV fractions obtained from lipopolysaccharide-stimulated monocytic THP-1 cells, and investigated the impact of storing EVs at 4 degrees C or -80 degrees C for up to one month on their concentration and stability. The concentration of EV fractions remained stable under the tested storage conditions, but the fluorescence intensity of labeled EVs stored at 4 degrees C began to decline within one day.
Extracellular vesicles (EVs) are of interest for a wide variety of biomedical applications. A major limitation for the clinical use of EVs is the lack of standardized methods for the fast and reproducible separation and subsequent detection of EV subpopulations from biofluids, as well as their storage. To advance this application area, fluorescence-based characterization technologies with single-EV resolution, such as high-sensitivity flow cytometry (HS-FCM), are powerful to allow assessment of EV fractionation methods and storage conditions. Furthermore, the use of HS-FCM and fluorescent labeling of EV subsets is expanding due to the potential of high-throughput, multiplex analysis, but requires further method development to enhance the reproducibility of measurements. In this study, we have applied HS-FCM measurements next to standard EV characterization techniques, including nanoparticle tracking analysis, to compare the yield and purity of EV fractions obtained from lipopolysaccharide-stimulated monocytic THP-1 cells by two EV isolation methods, differential centrifugation followed by ultracentrifugation and the exoEasy membrane affinity spin column purification. We observed differences in EV yield and purity. In addition, we have investigated the influence of EV storage at 4 degrees C or -80 degrees C for up to one month on the EV concentration and the stability of EV-associated fluorescent labels. The concentration of the in vitro cell derived EV fractions was shown to remain stable under the tested storage conditions, however, the fluorescence intensity of labeled EV stored at 4 degrees C started to decline within one day.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据