4.7 Article

Retrofitting of masonry walls by using a mortar joint technique; experiments and numerical validation

期刊

ENGINEERING STRUCTURES
卷 117, 期 -, 页码 58-70

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2016.03.001

关键词

Masonry wall; Double-leaf wall; Strengthening/repairing method; Earthquake damaged structures

资金

  1. China Scholarship Council (CSC)
  2. University Of Leeds - UK

向作者/读者索取更多资源

This paper presents research on a conventional but practical retrofitting method for masonry walls along with the numerical modelling of it under in-plane lateral shear compression loading. The latter is capable of predicting the experimental collapse load and overall behaviour quite accurately. The retrofitting approach is based on building a wall parallel to an existing single-leaf wall and bonding the two leaves together using a mortar (collar) joint, merging the two individual panels into a unified double-leaf wall. Experiments on this retrofitting approach for both undamaged and damaged masonry walls have been introduced in the present paper. The tests revealed that the pre-damage application can increase the strength by 50% while the post-damage one can restore the initial strength. A micro-scale numerical model has been devised by considering the bricks as rigid elements and the mortar joint as a nonlinear failure surface. The model was implemented in the commercial Finite Element (FE) software MIDAS FEA and the numerical results were verified against the available experimental data. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据