4.6 Review

The diagnostic value of conventional radiography and musculoskeletal ultrasonography in calcium pyrophosphate deposition disease: a systematic literature review and meta-analysis

期刊

OSTEOARTHRITIS AND CARTILAGE
卷 29, 期 5, 页码 619-632

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.joca.2021.01.007

关键词

Diagnostic accuracy; Ultrasonography; Conventional radiography; Calcium pyrophosphate deposition disease; Crystal arthropathy

向作者/读者索取更多资源

This study compared the accuracy of CR and US in diagnosing CPPD, with US showing higher sensitivity and slightly lower specificity than CR. Both techniques demonstrated excellent diagnostic accuracy and should be considered complementary in the diagnostic work-up of patients with CPPD.
Objective: To examine and compare the accuracy of conventional radiography (CR) and musculoskeletal ultrasonography (US) in the diagnosis of calcium pyrophosphate (CPP) crystals deposition disease (CPPD). DESIGN: A systematic search of electronic databases (PubMed, Embase, and Cochrane), conference abstracts and reference lists was undertaken. Studies which evaluated the accuracy of CR and/or US in the diagnosis of CPPD, using synovial fluid analysis (SFA), histology or classification criteria as reference tests were included. Subgroup analyses by anatomic site and by reference test were performed. Results: Twenty-six studies were included. Using SFA/histology as reference test, CR and US showed an excellent (CR AUC 1/4 0.889, 95%CI 1/4 0.811-0.967) and an outstanding (US AUC 1/4 0.954, 95%CI 1/4 0.907 -1.0) diagnostic accuracy (p < 0.01), respectively. Furthermore, US showed a higher sensitivity (0.85, 95% CI 1/4 0.79-0.90 vs 0.47, 95%CI 1/4 0.40-0.55) and only a little lower specificity (0.87, 95%CI 1/4 0.83-0.91 vs 0.95, 95%CI 1/4 0.92-0.97) than CR. A considerable heterogeneity between the studies was found, with adopted reference test being the main source of heterogeneity. In fact, subgroup analysis showed a significant change in the diagnostic accuracy of CR, but not of US, using Ryan and McCarty criteria or SFA/ histology as reference test (CR: AUC 1/4 0.956, 95%CI 1/4 0.925-1.0 vs AUC 1/4 0.889, 95%CI 1/4 0.828-0.950, respectively, p < 0.01) (US: AUC 1/4 0.922, 95%CI 1/4 0.842-1.0 vs AUC 1/4 0.957, 95%CI 1/4 0.865-1.0, respectively, p 1/4 0.08) Conclusions: Although US is more sensitive and a little less specific than CR for identifying CPP crystals, both these two techniques showed a great diagnostic accuracy and should be regarded as complementary to each other in the diagnostic work-up of patients with CPPD. @& nbsp;2021 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据