4.7 Article

Experimental investigation of progressive collapse resistance of one-way reinforced concrete beam-slab substructures under a middle-column-removal scenario

期刊

ENGINEERING STRUCTURES
卷 118, 期 -, 页码 28-40

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2016.03.051

关键词

Reinforced concrete frame structure; One-way beam-slab substructure; Progressive collapse resistance; Middle column removal scenario; Experimental investigation

资金

  1. National Basic Research Program of China (973 Program) [2012CB719703]
  2. National Natural Science Foundation of China [51578018, 51208011]
  3. Australian Research Council through an ARC Discovery Project [DP150100606]

向作者/读者索取更多资源

Floor systems composed of beams and slabs are critical structural elements of frame structures to resist progressive collapse. Previous experimental studies have focused mainly on beam-column or continuous-beam substructures and have ignored the influence of the slab. To study the progressive collapse-resisting mechanisms of reinforced concrete (RC) floor systems, seven 1/3-scaled one-way substructure specimens, including five beam-slab specimens and two continuous-beam specimens without slabs, were tested under a middle-column-removal scenario. The effects of various structural parameters, including sectional dimensions (beam height, slab width, and slab thickness) and seismic reinforcement, on the progressive collapse resistance were studied by analyzing material strains and load-displacement curves. Under small deformations, the progressive collapse resistance was largely affected by the beam height, slab width and seismic reinforcement in the beams. However, the effect of the slab width, upon exceeding the effective flange width, became insignificant. Note that increasing the slab thickness simultaneously increased the amount of slab reinforcement according to the minimum requirement of reinforcement ratio for slabs, such an increase will in turn enhanced the progressive collapse resistance. In addition, the existence of the slab led to an over-reinforced damage in the compressive zones of the beam ends, which accelerated the bending failure and the presence of the catenary action of the specimens. Under large deformations, the progressive collapse resistance was mainly influenced by the reinforcement area of the entire beam-slab section. The total reinforcement area of a beam-slab substructure designed to meet a higher seismic requirement was not significantly increased, and consequently, the progressive collapse resistance of the substructure under the catenary mechanism was not notably improved. This finding stands in stark contrast to those of previous tests of beam-column specimens without slabs. Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据