4.5 Article

Study on the vibration performances for a high temperature fiber F-P accelerometer

期刊

OPTICAL FIBER TECHNOLOGY
卷 62, 期 -, 页码 -

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.yofte.2021.102471

关键词

MEMS; Vibration detection; High temperature; SiC; Q-point

资金

  1. Major Technological Innovation Projects in Hubei Province [2017ACA167]

向作者/读者索取更多资源

This paper investigated a fiber F-P accelerometer for vibration detection in high temperature environments, such as aerospace and nuclear power. The sensor, based on MEMS technology, exhibited high accuracy in detecting vibration signals in different directions, with sensitivity and linearity being key characteristics. Experimental results showed excellent performance in terms of sensitivity, frequency repeatability errors, and linearity in both the main and lateral axes of the sensor.
In order to meet the vibration detection needs in high temperature environments such as aerospace, nuclear power, high temperature casting, etc., a fiber F-P accelerometer is investigated. This paper studies the vibration characteristics of a fiber-optic F-P high temperature sensor based on MEMS technology. It introduces the sensor mechanism, simulation, design and manufacturing process, and on this basis, deeply studies the vibration characteristics of the sensor in different directions. The sensitive part of the detection probe, essentially composed of a single-mode fiber and an SiC element sensitive to vibrations, constitutes the F-P resonant cavity. The thermal properties of all elements of the probe made it possible to detect vibrations in the probe main and lateral axis in the temperature range of 27 degrees C to 800 degrees C. In the main measurement axis of the probe, experimental results show that the sensor can detect vibration signals with high accuracy. It has a sensitivity of about 370 mV/g in the flat range of 100 to 1000 Hz and its natural frequency is about 3750 Hz. The sensor has frequency repeatability errors of less than 0.5%, and excellent linearity of about 1 between input and output frequencies. Arranged on its lateral axis, the probe shows a working frequency range of 100 to 700 Hz and its resonance frequency is approximately 1450 Hz. In the lateral axis, it reproduces all input frequencies with a linearity of 1 and at an amplitude of 11% of that of the main axis. The field application shows that the relative error on the frequency measurements is less than 4% in both axes, and the absolute error less than 5 Hz according to the technical index of the test site. To obtain this stability and good precision in the two measurement axes, the method of automatic and rapid tracking of the Q-point was used as demodulation algorithm.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据