4.7 Article

Axial and lateral stress-strain model for concrete-filled steel tubes with FRP jackets

期刊

ENGINEERING STRUCTURES
卷 126, 期 -, 页码 365-378

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2016.07.059

关键词

Concrete confinement; Concrete-filled steel tube; Confining stress; FRP jacket; Lateral strain of concrete

向作者/读者索取更多资源

In a concrete-filled steel tube under axial compression, since the steel tube has a larger Poisson's ratio than the concrete, delamination at the steel-concrete interface occurs and the steel tube is ineffective in providing confinement at the elastic stage. For resolving this problem and enhancing the concrete confinement, the provision of an external FRP (fiber reinforced polymer) jacket to restrict the lateral expansion of the steel tube is an effective means. Herein, to investigate the effectiveness of FRP-jacketed steel tube confinement, a theoretical model for evaluating the lateral strain, confining stress and axial stress in a concrete filled steel tube with FRP jacket at various stages of loading is developed. The theoretical model is first applied to analyze specimens tested by other researches to verify its accuracy and then used to work out the FRP confining stiffness required to eliminate steel-concrete delamination and the FRP confining stiffness required to achieve Level I ductility (no strain softening at the inelastic stage until failure). (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据