4.6 Article

Dual 2-Hydroxypropyl-β-Cyclodextrin and 5,10,15,20-Tetrakis (4-Hydroxyphenyl) Porphyrin System as a Novel Chiral-Achiral Selector Complex for Enantioseparation of Aminoalkanol Derivatives with Anticancer Activity in Capillary Electrophoresis

期刊

MOLECULES
卷 26, 期 4, 页码 -

出版社

MDPI
DOI: 10.3390/molecules26040993

关键词

anticancer drug; capillary electrophoresis; chiral selectors; drug monitoring

资金

  1. WUM in Poland

向作者/读者索取更多资源

In this study, a dual chiral-achiral selector complex was successfully developed for the determination of enantiomers of two potential anticancer agents. The method demonstrated high separation selectivity and efficiency, allowing for quick analysis of the compounds within a short timeframe.
In this study, a complex consisting of 2-hydroxypropyl-beta-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin, (named dual chiral-achiral selector complex) was used for the determination of two novel potential anticancer agents of (I) and (II) aminoalkanol derivatives. This work aimed at developing an effective method that can be utilized for the determination of I (S), I (R), and II (S) and II (R) enantiomers of (I) and (II) compounds through the use of a dual chiral-achiral selector complex consisting of hydroxypropyl-beta-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin system by applying capillary electrophoresis. This combination proved to be beneficial in achieving high separation selectivity due to the combined effects of different modes of chiral discrimination. The enantiomers of (I) and (II) compounds were separated within a very short time of 3.6-7.2 min, in pH 2.5 phosphate buffer containing 2-hydroxypropyl-beta-cyclodextrin and 5,10,15,20-tetrakis (4-hydroxyphenyl) porphyrin system at a concentration of 5 and 10 mM, respectively, at 25 degrees C and +10 kV. The detection wavelength of the detector was set at 200 nm. The LOD for I (S), I (R), II (S), and II (R) was 65.2, 65.6, 65.1, and 65.7 ng/mL, respectively. LOQ for I (S), I (R), II (S), and II (R) was 216.5, 217.8, 217.1, and 218.1 ng/mL, respectively. Recovery was 94.9-99.9%. The repeatability and reproducibility of the method based on the values of the migration time, and the area under the peak was 0.3-2.9% RSD. The stability of the method was determined at 0.1-4.9% RSD. The developed method was used in the pilot studies for determining the enantiomers I (S), I (R), II (S), and II (R) in the blood serum.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据