4.5 Review

Robotic-arm assisted total knee arthroplasty is associated with improved accuracy and patient reported outcomes: a systematic review and meta-analysis

期刊

KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
卷 30, 期 8, 页码 2677-2695

出版社

SPRINGER
DOI: 10.1007/s00167-021-06464-4

关键词

Knee; Arthroplasty; Robotic; Knee alignment; Knee balancing techniques; Outcome; Complications

向作者/读者索取更多资源

This study compared the accuracy of component positioning, patient-reported outcomes, and complications of robotic-arm assisted total knee arthroplasty with manual TKA and analyzed the associated learning curve. The results showed that RATKA performed better in terms of component positioning accuracy and patient-reported outcomes.
This systematic review and meta-analysis were conducted to compare the accuracy of component positioning, alignment and balancing techniques employed, patient-reported outcomes, and complications of robotic-arm assisted total knee arthroplasty (RATKA) with manual TKA (mTKA) and the associated learning curve. Searches of PubMed, Medline and Google Scholar were performed in October 2020 using PRISMA guidelines. Search terms included robotic, knee and arthroplasty. The criteria for inclusion were published clinical research articles reporting the learning curve for RATKA and those comparing the component position accuracy, alignment and balancing techniques, functional outcomes, or complications with mTKA. There were 198 articles identified, following full text screening, 16 studies satisfied the inclusion criteria and reported the learning curve of rTKA (n=5), component positioning accuracy (n=6), alignment and balancing techniques (n=7), functional outcomes (n=7), or complications (n=5). Two studies reported the learning curve using CUSUM analysis to establish an inflexion point for proficiency which ranged from 7 to 11 cases and there was no learning curve for component positioning accuracy. The meta-analysis showed a significantly lower difference between planned component position and implanted component position, and the spread was narrower for RATKA compared with the mTKA group (Femur coronal: mean 1.31, 95% confidence interval (CI) 1.08-1.55, p<0.00001; Tibia coronal: mean 1.56, 95% CI 1.32-1.81, p<0.00001). Three studies reported using different alignment and balancing techniques between mTKA and RATKA, two studies used the same for both group and two studies did not state the methods used in their RATKA groups. RATKA resulted in better Knee Society Score Powered by Editorial Manager (R) and ProduXion Manager (R) from Aries Systems Corporation compared to mTKA in the short-to-mid-term follow up (95%CI [- 1.23, - 0.51], p=0.004). There was no difference in arthrofibrosis, superficial and deep infection, wound dehiscence, or overall complication rates. RATKA demonstrated improved accuracy of component positioning and patient-reported outcomes. The learning curve of RATKA for operating time was between 7 and 11 cases. Future well-powered studies on RATKAs should report on the knee alignment and balancing techniques utilised to enable better comparisons on which techniques maximise patient outcomes. Level of evidence III.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据