4.4 Article

Defining the filter parameters for phase-amplitude coupling from a bispectral point of view

期刊

JOURNAL OF NEUROSCIENCE METHODS
卷 350, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.jneumeth.2020.109032

关键词

Cross-frequency coupling; Bicoherence; Phase-amplitude coupling

资金

  1. ERC [715945]
  2. NWO (Netherlands Organisa-tion for Scientific Research) VIDI-grant FirSTeps [016.156.346]
  3. Faculty of Behavioural and Movement Sciences (Vrije Universiteit Amsterdam)
  4. German Research Foundation [DFG] [SFB936/Z3, TRR169/C1/B4]
  5. European Research Council (ERC) [715945] Funding Source: European Research Council (ERC)

向作者/读者索取更多资源

Comparing PAC estimates under different filter settings, it was found that a 1:1 ratio yielded the best results, avoiding signal smearing. The results were essentially identical to bicoherence estimates, providing insights on setting PAC filters effectively.
Background: Two measures of cross-frequency coupling are phase-amplitude coupling (PAC) and bicoherence. The estimation of PAC with meaningful bandwidth for the high-frequency amplitude is crucial in order to avoid misinterpretations. While recommendations on the bandwidth of PAC's amplitude component exist, there is no consensus yet. Theoretical relationships between PAC and bicoherence can provide insights on how to set PAC's filters. New method: To illustrate this, PAC estimated from simulated and empirical data are compared to the bispectrum. We used simulations replicated from earlier studies and empirical data from human electro-encephalography and rat local field potentials. PAC's amplitude component was estimated using a filter bandwidth with a ratio of (1) 2:1, (2) 1:1, or (3) 0.5:1 relative to the phase frequency. Results: For both simulated and empirical data, PAC was smeared over a broad frequency range and not present when the estimates comprised a 2:1- and 0.5:1-ratio, respectively. In contrast, the 1:1-ratio accurately avoids smearing and results in clear signals of cross-frequency coupling. Bicoherence estimates were found to be essentially identical to PAC calculated with the recommended frequency setting. Comparison with existing method(s): Earlier recommendations on filter settings of PAC lead to estimates which are smeared in the frequency domain, which makes it difficult to identify cross-frequency coupling of neural processes operating in narrow frequency bands. Conclusions: We conclude that smearing of PAC estimates can be avoided with a different choice of filter settings by theoretically relating PAC to bicoherence.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据