4.4 Article

Genotype and residual enzyme activity in medium-chain acyl-CoA dehydrogenase (MCAD) deficiency: Are predictions possible?

期刊

JOURNAL OF INHERITED METABOLIC DISEASE
卷 44, 期 4, 页码 916-925

出版社

WILEY
DOI: 10.1002/jimd.12368

关键词

confirmation diagnostics; fatty acid oxidation disorders; MCAD deficiency; medium‐ chain acylcarnitines; newborn screening

资金

  1. Projekt DEAL

向作者/读者索取更多资源

This study confirmed the diagnosis of MCADD through enzyme testing and genetic analysis, showing a correlation between C6 and C8 acylcarnitine species and MCAD activity and disease severity. Additionally, 20 new variants were identified and functionally classified based on their effect on enzyme function.
Medium-chain acyl-CoA dehydrogenase deficiency (MCADD) is the most common defect of mitochondrial beta-oxidation. Confirmation diagnostics after newborn screening (NBS) can be performed either by enzyme testing and/or by sequencing of the ACADM gene. Here, we report the results from enzyme testing in lymphocytes with gene variants from molecular analysis of the ACADM gene and with the initial acylcarnitine concentrations in the NBS sample. From April 2013 to August 2019, in 388 individuals with characteristic acylcarnitine profiles suggestive of MCADD the octanoyl-CoA-oxidation was measured in lymphocytes. In those individuals with residual activities <50%, molecular genetic analysis of the ACADM gene was performed. In 50% of the samples (195/388), MCADD with a residual activity ranging from 0% to 30% was confirmed. Forty-five percent of the samples (172/388) showed a residual activity >35% excluding MCADD. In the remaining 21 individuals, MCAD residual activity ranged from 30% to 35%. The latter group comprised both heterozygous carriers and individuals carrying two gene variants on different alleles. Twenty new variants could be identified and functionally classified based on their effect on enzyme function. C6 and C8 acylcarnitine species in NBS correlated with MCAD activity and disease severity. MCADD was only confirmed in half of the cases referred suggesting a higher false positive rate than expected. Measurement of the enzyme function in lymphocytes allowed fast confirmation diagnostics and clear determination of the pathogenicity of new gene variants. There is a clear correlation between genotype and enzyme function underlining the reproducibility of the functional measurement in vitro.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据