4.5 Article

A novel method of donor.recipient size matching in pediatric heart transplantation: A total cardiac volume.predictive model

期刊

JOURNAL OF HEART AND LUNG TRANSPLANTATION
卷 40, 期 2, 页码 158-165

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.healun.2020.11.002

关键词

pediatric heart transplantation; pediatric heart failure; 3D imaging; size matching; total cardiac volume

资金

  1. National Institute of Healths [1R01HL147957-01]

向作者/读者索取更多资源

By utilizing anthropometric measurements and 1-view CXR cardiac measurements, accurate predictions of total cardiac volume (TCV) for donor candidates can be made. Model C had the most accurate prediction of TCV and outperformed other models.
BACKGROUND: The pediatric heart transplant community uses weight-based donor-to-recipient size matching almost exclusively, despite no evidence to validate weight as a reliable surrogate of cardiac size. Donor size mismatch is the second most common reason for the refusal of donor hearts in current practice (similar to 30% of all refusals). Whereas case-by-case segmentation of total cardiac volume (TCV) by computed tomography (CT) for direct virtual transplantation is an attractive option, it remains limited by the unavailability of donor chest CT. We sought to establish a predictive model for donor TCV on the basis of anthropomorphic and chest X-ray (CXR) cardiac measures. METHODS: Banked imaging studies from 141 subjects with normal CT chest angiograms were obtained and segmented using 3-dimensional modeling to derive TCV. CXR data were available for 62 of those subjects. A total of 3 predictive models of TCV were fit through multiple linear regression using the following variables: Model A (weight only); Model B (weight, height, sex, and age); Model C (weight, height, sex, age, and 1-view anteroposterior CXR maximal horizontal cardiac width). RESULTS: Model C provided the most accurate prediction of TCV (optimism corrected R-2 = 0.99, testing set R-2 = 0.98, mean absolute percentage error [MAPE] = 8.6%) and outperformed Model A (optimism corrected R-2 = 0.94, testing set R-2 = 0.94, MAPE = 16.1%) and Model B (optimism corrected R-2 = 0.97, testing set R-2 = 0.97, MAPE = 11.1%). CONCLUSIONS: TCV can be predicted accurately using readily available anthropometrics and a 1-view CXR from donor candidates. This simple and scalable method of TCV estimation may provide a reliable and consistent method to improve donor size matching. (C) 2020 International Society for Heart and Lung Transplantation. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据