Obtaining the heat loss coefficient of a dwelling using its heating system (integrated coheating)

期刊

ENERGY AND BUILDINGS
卷 117, 期 -, 页码 1-10

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2016.02.013

关键词

Coheating; Heat loss coefficient; Thermal performance; Energy signature; Heating system; Performance gap; Heat meter; Energy efficiency; Building fabric; Whole house heat loss

向作者/读者索取更多资源

This paper presents the methodology, along with some of the initial findings and observations from tests performed on two dwellings, of differing construction and form, in which a coheating test was performed using the dwelling's central heating system; this method is referred to as integrated coheating. Data obtained during the integrated coheating tests using a dwelling's heating system have been compared with data obtained during electric coheating of the same dwelling. In one instance, integrated coheating test data from one dwelling was compared to a similar adjoining control dwelling that was simultaneously subject to an electric coheating test. The results show a good agreement between the heat loss coefficients (HLC) obtained using a dwelling's own heating system and those obtained through electrical coheating. Initial analysis suggests the HLC estimate obtained from integrated coheating is likely to be more representative of how a dwelling performs in-use. The findings question the appropriateness of comparing current steady-state HLC predictions to those derived from in-use monitoring data. Integrated coheating has the potential to provide a more cost-effective and informative indication of whole house heat loss than electric coheating, as it enables in situ quantification of both fabric and heating system performance. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据