4.7 Article

Evaluation of the Accelerate Pheno System for Rapid Identification and Antimicrobial Susceptibility Testing of Positive Blood Culture Bottles Inoculated with Primary Sterile Specimens from Patients with Suspected Severe Infections

期刊

JOURNAL OF CLINICAL MICROBIOLOGY
卷 59, 期 5, 页码 -

出版社

AMER SOC MICROBIOLOGY
DOI: 10.1128/JCM.02637-20

关键词

susceptibility; bacterial identification; blood culture; primary sterile specimens; rapid tests

向作者/读者索取更多资源

The study evaluated the performance of the Accelerate Pheno system for identification and AST from positive blood culture bottles inoculated with primary sterile specimens, showing that the system can accelerate pathogen identification and antimicrobial susceptibility testing, especially for hospitals without on-site microbiology laboratories. However, inclusion of nonblood specimens with a high likelihood of polymicrobial infections may lead to inferior performance.
The Accelerate Pheno system is approved for rapid identification and phenotypic antimicrobial susceptibility testing (AST) of microorganisms grown from positive blood cultures inoculated with blood from septic patients. We evaluated the performance of the system for identification and AST from positive blood culture bottles inoculated with primary sterile nonblood specimens from patients with suspected severe infections. One hundred positive blood culture bottles with primary sterile specimens (63 cerebrospinal fluids, 16 ascites, 7 pleural fluids, 4 vitreous fluids, 5 joint aspirates, and 5 other aspirates) from 100 patients were included. Pathogen identification was in agreement with conventional methods for 72 of 100 cultures (72%) and for 81 of 112 (72%) pathogens when considering all pathogens and for 72 of 92 (78%) cultures and 81 of 104 (78%) pathogens when considering on-panel pathogens only. Eight of 31 isolates (26%) not identified by APS were pathogens not included in the APS panel. APS and conventional methods accordingly identified all pathogens from two of nine polymicrobial cultures (22%). APS generated antimicrobial resistance results for 57 pathogens of 57 cultures. The overall category agreement between APS and culture-based AST was 91.2%; and the rate for minor errors was 6.9%, for major was 1.7%, and for very major errors was 0.2%. APS may accelerate pathogen identification and phenotypic AST from positive blood culture bottles inoculated with primary sterile specimens from patients with serious infections, especially for hospitals without an on-site microbiology laboratory. However, the inclusion of nonblood specimens with a high likelihood of polymicrobial infections may result in an inferior performance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据