4.7 Article

Design and tri-objective optimization of a hybrid efficient energy system for tri-generation, based on PEM fuel cell and MED using syngas as a fuel

期刊

JOURNAL OF CLEANER PRODUCTION
卷 290, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jclepro.2020.125205

关键词

Zeotropic mixtures; Tri-objective optimization; Biomass-based PEM fuel Cell; MED; Multi-generational system

向作者/读者索取更多资源

This study proposes a novel solution to enhance the performance and cost-effectiveness of a biomass-based proton exchange membrane fuel cell by integrating it with a gasifier, a multi-effect desalination unit, and a series two-stage organic Rankine cycle. A comparative parametric study reveals R601a-C-2 Butene as the best STORC working fluid from thermodynamic and economic perspectives. The integrated system shows considerably lower CO2 index and achieves a tri-objective optimization point with minimum total cost rate, maximum exergy efficiency, and produced freshwater.
This article presents a novel solution to enhance the performance and cost-effectiveness of a biomass-based proton exchange membrane (PEM) fuel cell. It investigates the proposed configuration from energy, exergy, economic, and environmental aspects. The idea is conducted by the integration of the proposed system with a gasifier, a multi-effect desalination (MED) unit, and a series two-stage organic Rankine cycle (STORC) using various zeotropic mixtures for the use of waste heat for heat, power, and freshwater production. A comparative parametric study is carried out not only to evaluate the effect of main parameters on the performance of the proposed system but also to determine the best zeotropic mixture from different standpoints. In addition, the tri-objective optimization using a genetic algorithm approach is implemented to the system to ascertain the best operating condition to minimize the total cost rate and maximize the exergy efficiency and the produced fresh water simultaneously. The results of a comparative parametric study reveal the superiority of R601a-C-2 Butene (75%-25%) among various STORC working fluids from thermodynamic and economic points of view. The results further show that the proposed integrated system has a considerably lower CO2 index compared to the same system without the STORC unit. For the final tri-objective optimization point, while the minimum total cost rate is 64.91 $/h, the maximum exergy efficiency and produced freshwater are 23.43% and 162.86 m(3)/day, respectively. Furthermore, the scatter distribution of the main decision variable reveals that moisture content and current density are not a sensible variable, and their optimal points are distributed in the whole domain. (C) 2020 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据