4.7 Article

Constructal design of different ribs for thermo-fluid performance enhancement of a solar air heater (SAH)

期刊

出版社

ELSEVIER FRANCE-EDITIONS SCIENTIFIQUES MEDICALES ELSEVIER
DOI: 10.1016/j.ijthermalsci.2020.106655

关键词

Constructal theory; T-rib; Solar air heater; SST k - omega model

向作者/读者索取更多资源

In this study, the constructal theory was utilized to develop six new types of ribs for a solar air heater, and their performance was numerically investigated using computational fluid dynamics. It was found that the T-rib showed the highest Nusselt number and lowest friction factor among all considered ribs, leading to enhanced heat transfer efficiency in the solar air heater.
In this paper, the constructal theory has been applied to evolve six new types of ribs (T-rib, left arm inclined T-rib, right arm inclined T-rib, Y-rib, concave and convex T-ribs) for a solar air heater (SAH). The fluid flow and heat transfer characteristics of the SAH with these ribs have been numerically investigated by solving the mass, momentum, energy, and turbulence equations employing the finite volume technique of ANSYS Fluent R16. The SST k -omega model has been used to solve the turbulence quantities, especially, the turbulent kinetic energy (k), and the specific dissipation rate (omega). The performance of the SAH has been obtained by varying different prominienet parameters of importance, such as the pitch (20 mm-90 mm), stem height (3 mm-11 mm), the inclination angle of the rib (0 degrees-60 degrees) and Reynolds number (5000-18,000). The optimal lengths for the pitch (i.e., 80 mm) and for the stem height (i.e., 8 mm) have been found out for T-ribs. It has been observed that the Nusselt number for T-rib increases by 191% in a range of Reynolds number, 5000-18,000, and at the optimum pitch and stem height. It is also observed that the Nusselt number marginally increases with the inclination angle of the rib. The concave T-rib and convex T-ribs have been evolved from the basic T-rib. Among all the considered ribs, the T-rib is found to be the best heat transfer enhancer keeping the friction factor at a low value. We found a higher Nusselt number and a lower friction factor for the present SAH with the T-ribs, as compared to that of the SAHs considered by previous researchers. The thermo-hydraulic performance (THPP) of a SAH with present rib (i.e., T-rib or the concave T-rib) has been observed to be more than SAH with other shapes of ribs used by previous researchers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据