4.7 Article

Quantitative susceptibility-weighted imaging may be an accurate method for determining stroke hypoperfusion and hypoxia of penumbra

期刊

EUROPEAN RADIOLOGY
卷 31, 期 8, 页码 6323-6333

出版社

SPRINGER
DOI: 10.1007/s00330-020-07485-2

关键词

Magnetic resonance imaging; Stroke; Hypoxia

资金

  1. Natural Scientific Foundation of China [81871342, 81971590, 81901728]

向作者/读者索取更多资源

SWIvolume-DWI mismatch showed higher diagnostic efficacy than SWIASPECTS-DWI mismatch in defining the ischemic penumbra and demonstrated good consistency with PWI-DWI mismatch in acute ischemic stroke. Quantitation of APCVs using SWIM provided an accurate method for determining hypoperfusion and reflected the hypoxia of penumbra reliably. Positive correlations were found between SWIvolume-DWI and PWI-DWI mismatch, as well as between SWI-volume and Tmax > 6 s volume. Negative correlations were found between SWIvolume-DWI mismatch and NIHSS, as well as between SWIASPECTS-DWI mismatch and NIHSS.
Objectives To quantitatively evaluate the volume of the ischemic penumbra using susceptibility-weighted imaging and mapping (SWIM) of asymmetrical prominent cortical veins (APCVs) in patients with acute ischemic stroke. Methods Eighty-five eligible patients with acute ischemic stroke on admission within 12 h from symptom onset were studied. The APCVs on SWIM were quantitatively (SWI-volume) and semi-quantitatively (SWI-Alberta Stroke Program Early CT Score, SWI-ASPECTS) evaluated to calculate mismatch. To assess the diagnostic efficacy of APCVs on SWIM, comparative analyses were performed between SWIvolume-DWI mismatch and SWIASPECTS-DWI mismatch, using PWI-DWI mismatch as a reference. Correlations were calculated between the mismatches, as well as between SWI-volume and time-to-maximum (Tmax) > 6 s volume. Additionally, each of these mismatches was correlated with the National Institute of Health Stroke Scale (NIHSS). Results The sensitivity, negative predictive value, and accuracy of SWIvolume-DWI mismatch were demonstrably higher than SWIASPECTS-DWI mismatch (100% vs. 53.7%, 100% vs. 9.5%, 97.7% vs. 54.5%, respectively). A significant positive correlation was found between SWIvolume-DWI and PWI-DWI mismatch (r = 0.691, p < 0.01), as well as between SWI-volume and Tmax > 6 s volume (r = 0.786, p < 0.001). A significant negative correlation was found between SWIvolume-DWI mismatch and NIHSS (r = - 0.360, p = 0.022), as well as between SWIASPECTS-DWI mismatch and NIHSS (r = - 0.499, p = 0.001). Conclusions SWIvolume-DWI mismatch had higher diagnostic efficacy than SWIASPECTS-DWI mismatch in defining the ischemic penumbra and showed good consistency with PWI-DWI mismatch in acute ischemic stroke. Quantitation of APCVs using SWIM provided an accurate method for determining hypoperfusion and provided a reliable method to reflect the hypoxia of penumbra.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据