4.1 Article

Bruch's membrane opening-minimum rim width: An alternative OCT biomarker study for multiple sclerosis

期刊

EUROPEAN JOURNAL OF OPHTHALMOLOGY
卷 31, 期 4, 页码 2141-2149

出版社

SAGE PUBLICATIONS LTD
DOI: 10.1177/1120672121996638

关键词

Multiple sclerosis; spectral-domain optical coherence tomography; Bruch's membrane opening-minimum rim width; retinal nerve fiber layer; anatomic positioning system

向作者/读者索取更多资源

The study investigated the potential of novel OCT parameters as alternative biomarkers in MS patients, with APS-RNFL technique showing slightly more reliability than S-RNFL technique, while BMO-MRW was not found to be a successful alternative.
Purpose: Bruch's membrane opening-minimum rim width (BMO-MRW) and RNFL measured using anatomic positioning system (APS-RNFL) are novel OCT methods and remained unexplored in MS patients. To investigate the novel parameters of spectral-domain OCT as an alternative biomarker in patients with multiple sclerosis (MS). Methods: Retrospective cohort study; participants consisted of relapsing-remitting MS (RRMS) patients and healthy controls (HC). Eyes were classified according to the presence of MS and previous optic neuritis (ON). Measurements of standard peripapillary RNFL (S-RNFL), BMO-MRW, and APS-RNFL were performed. Result: A total of 244 eyes of 122 participants (MS-patients: 63, HC: 59) were included in the study. Fifty-one eyes had a history of previous ON. In almost all measured parameters, neuroretinal rim thicknesses were observed the thinnest in eyes with ON history between all subgroups. S-RNFL and APS-RNFL techniques showed the difference in neuroretinal rim thickness in all three subjects (ON+, ON-, and HC). However, BMO-MRW, on the other hand, could not distinguish between ON(-) patients and HC. The relationship between OCT parameters and EDSS were observed only in eyes with an ON history in all three techniques. A meaningful model with 78% accuracy was obtained by using only the OCT parameters as risk factors. In the ROC analysis, no parameters were found to have acceptable high sensitivity and specificity. BMO-MRW was statistically weaker in every aspect than other RNFL techniques. Conclusion: The novel APS-RNFL technique appears to be a bit more reliable alternative to S-RNFL technique to support therapeutic decision-making in MS. BMO-MRW has not been found as a successful alternative to S-RNFL.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据