4.7 Article

Multi-objective optimal design and seismic performance of negative stiffness damped outrigger structures considering damping cost

期刊

ENGINEERING STRUCTURES
卷 229, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2020.111615

关键词

Damped outrigger; Negative stiffness; Multi-objective optimization; Cost saving; Seismic performance

资金

  1. State Key Laboratory of Disaster Reduction in Civil Engineering of China [SLDRCE19-B-16, SLDRCE13-MB-01]
  2. China Scholarship Council

向作者/读者索取更多资源

This paper improves the seismic performance of conventional damped outriggers by incorporating negative stiffness in parallel with viscous dampers, resulting in higher damping effects. The optimized NSDO is used to retrofit existing CO structures, significantly reducing damping costs and improving structural performance.
In this paper, the seismic performance of conventional damped outrigger (CDO) is improved by incorporating negative stiffness (NS) in parallel with the viscous damper. The applied negative stiffness spring upgrades the classical Maxwell damping element, which is used to describe the assembly of outrigger viscous damper and perimeter columns, to negative stiffness amplifying damper with higher damping effect. Tall buildings with such negative stiffness damped outrigger (NSDO) is described in the state space expression of the structure-outrigger-excitation augmented assembly, and the root-mean-square (RMS) responses of NSDO structures are parametrically studied to develop a direct connection between outrigger parameters and structural seismic responses. Based on these results, a multi-objective optimization method with both performance and economic objectives-reducing harmful inter-story drift and structural acceleration simultaneously with less outrigger damping cost-is proposed. Finally, this optimally designed NSDO is used to retrofit existing conventional outrigger (CO) structures as a supplemental energy dissipation outrigger. The performance of this retrofitted structure is studied and compared with that retrofitted by optimal CDO under numerous real earthquake records. Result indicates the CO structure retrofitted by NSDO substantially saves the outrigger damping cost of CDO by 85.9%, and further decreases the harmful drift and structural acceleration responses over 51% and 29%, respectively. Although optimal design of NSDO for strong earthquakes alone is the focus of this study, it is shown that NSDO is able to reduce wind-induced maximum acceleration by 33% without amplifying wind-induced maximum harmful drift.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据