4.6 Article

Uncovering the behavior of screen-printed carbon electrodes modified with polymers molecularly imprinted with lipopolysaccharide

期刊

ELECTROCHEMISTRY COMMUNICATIONS
卷 124, 期 -, 页码 -

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.elecom.2021.106965

关键词

Modified screen-printed carbon electrodes; Lipopolysaccharides; Molecularly imprinted polymers; Electrochemical detection

资金

  1. Ministry of Education and Research through UEFISCDI [TE 123/2018-BACTERIOSENS, 255PED/2020 TOXINSENS]

向作者/读者索取更多资源

This pioneering study describes the fabrication of screen-printed carbon electrodes modified with polymers molecularly imprinted with lipopolysaccharide to detect endotoxins derived from specific Gram-negative bacteria. The biosensors detected lipopolysaccharides derived from Pseudomonas Aeruginosa with high specificity, while the response to the same endotoxin derived from Escherichia coli was quite different compared to control sensors.
In the context of global issues concerning pathogen contamination of surface and ground waters, this pioneering study describes the fabrication of screen-printed carbon electrodes modified with polymers molecularly imprinted with lipopolysaccharide in an attempt to detect endotoxins derived from specific Gram-negative bacteria. The biosensors detected lipopolysaccharides derived from Pseudomonas Aeruginosa with high speci-ficity, relative to control sensors, while the response to the same endotoxin derived from Escherichia coli was quite different.