4.7 Article

Structural performance of dowelled cross-laminated timber hold-down connections with increased row spacing and end distance

期刊

CONSTRUCTION AND BUILDING MATERIALS
卷 271, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.conbuildmat.2020.121595

关键词

CLT; Dowelled connections; Hold-down; Ductility; Overstrength; Displacement capacity; Fastener spacing

资金

  1. Speciality Wood Products Partnership
  2. New Zealand Douglas-Fir Association
  3. Australian Research Council Future Timber Hub
  4. New Zealand Commonwealth Scholarship and Fellowship Plan

向作者/读者索取更多资源

The experimental study enhanced the ductility of dowelled connections by increasing the spacing and end distance specified by design standards, while maintaining comparable connection strength. The most significant effect was observed in the five-layer CLT specimens.
This paper presents an experimental study to assess the structural performance of dowelled cross-laminated timber (CLT) hold-down connections that are critical components for a CLT shear wall under seismic loads. It aims to quantify the enhanced connection performance by increasing row spacing and end distance in the dowel layout compared with the standard spacing/distance specified by design standards. A total of 47 dowelled hold-down connection specimens with standard and increased row spacing and end distance in three-, five-, and seven-layer CLT layups were tested under monotonic and cyclic loading. Additional attempt was also made to investigate the benefits of applying screw reinforcement to deter the onset of potential brittle failure modes or mode cross-over. The increased row spacing and end distance provided comparable connection strength but significantly increased ductility. Displacement capacity and ductility increased by 35% and 20%, respectively and the effect was most pronounced in the five-layer CLT specimens. Dowel embedment tests were performed to verify the CLT Handbook equation and to determine theoretical overstrength. The maximum connection overstrength factor was 1.70 and the average was 1.61. Reinforcement by fully threaded inclined screws or the use of threaded dowels with nuts can further enhance the connection performance. (C) 2020 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者